![Balluff BNI EIP-104-105-Z015 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/balluff/bni-eip-104-105-z015/bni-eip-104-105-z015_user-manual_469608017.webp)
Balluff Network Interface EtherNet/IP
™
www.balluff.com
16
6
Display
6.10.
Module
information
•
By short-time keypress on arrow key you can scroll through module information
menu.
•
Informations are the product name, the module revisions and the MacID.
6.11.
General
Informations
•
Longtime keypress for „fast scrolling“ in editing mode
•
10 seconds without keypress results in leaving actual screen and entering the
default screen mode (4
th
octet of ip address). Unsaved changes gets lost
•
Differences between new configuration and the configuration the module is working
with are shown by a unequal-symbol. In this case the time to default screen is only
5 seconds.
•
In editing mode the screen flashes. In fast scroll mode the screen is flickering
•
If the module receives a single ping, the word “ping” is shown in the display screen
for a few seconds. Afterwards the screen is reset to the screen which had been
shown before. By short-time key press on set key the ping-mode can be left
preterm.
•
If the m
odule receives a double ping, the word “ping” is shown in the display. This
screen can be left only by short-time key press on set key. The screen shown
before ping gets viewed again.
•
The Led function at the display leds can be defined user specific by setting some
bits in the process data inputs.
(see Bitlayout, chapter 8 „Annex“)
•
The function plc-lock can also be used by setting a bit in the process data inputs.
(see Bitlayout, chapter 8 „Annex“)
Note
:
Editing mode can not be chosen in display if the plc lock bit in process data
inputs is
(see Bitlayout, chapter 8 „Annex“)
BNI
EIP-302-
100-Z016
Version
SW: x.x
HW: x.x
MAC-ID
XX : XX : XX :
XX : XX : XX
…