Balluff Network Interface / DeviceNet Fieldbus Distributor

4

Safety

The BNI DNT-... serves as a decentral in- and output module for connecting to a DeviceNet 
network.

Installation and startup

Installation and startup are to be performed only by trained specialists. Any damage resulting 
from unauthorized manipulation or improper use voids the manufacturer's guarantee and war-
ranty.
The device is an equipment in accordance with EMC Class A. Such equipment may generate RF 
noise. The operator must take precautionary measures accordingly.
The device must be powered only using an approved power supply 

(see "Technical data" on 

page 1)

. Only approved cables may be used.

Operation and testing

The operator is responsible for observing local prevailing safety regulations.
When defects and non-clearable faults in the device occur, take it out of service and secure 
against unauthorized use. 
Approved use is ensured only when the housing is fully installed.

Caution!

The pictogram used with the word "Caution" warns of a possible hazardous situation 

affecting the health of persons or equipment damage. Ignoring these warnings can 

result in injury or equipment damage.

Always observe the described measures for preventing this danger.

2.1  Intended use

2.2  General safety 

notes

2.3  Meaning of the 

warnings

2

Содержание BNI DNT-104-000-Z004

Страница 1: ...BNI DNT 104 000 Z004 BNI DNT 202 000 Z005 BNI DNT 302 000 Z005 BNI DNT 305 000 Z005 Short Guide English...

Страница 2: ...ons 3 Safety 4 2 1 Intended use 4 2 2 General safety notes 4 2 3 Meaning of the warnings 4 Getting Started 5 3 1 Connection overview 5 3 2 Mechanical connection 8 3 3 Electrical connection 9 3 4 Bus c...

Страница 3: ...by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Numbers Decimal numbers are shown without additional indicators e g 123...

Страница 4: ...st be powered only using an approved power supply see Technical data on page 12 Only approved cables may be used Operation and testing The operator is responsible for observing local prevailing safety...

Страница 5: ...Fig 1 Connection overview BNI DNT 104 000 Z004 1 Mounting hole 2 Baud rate switch 3 Address switches 4 7 8 Bus OUT 5 Status LED 6 Standard I Port 4 7 Standard I Port 5 8 Standard I Port 6 9 Standard I...

Страница 6: ...202 000 Z005 1 Mounting hole 2 Baud rate switch 3 Address switches 4 7 8 Bus OUT 5 Status LED 6 Standard O Port 4 7 Standard O Port 5 8 Standard O Port 6 9 Standard O Port 7 10 Standard O Port 3 11 S...

Страница 7: ...302 000 Z005 1 Mounting hole 2 Baud rate switch 3 Address switches 4 7 8 Bus OUT 5 Status LED 6 Standard I O Port 4 7 Standard I O Port 5 8 Standard I O Port 6 9 Standard I O Port 7 10 Standard I O P...

Страница 8: ...ing hole 2 Baud rate switch 3 Address switches 4 7 8 Bus OUT 5 Status LED 6 Standard I Port 2 7 Standard I Port 3 8 Standard O Port 2 9 Standard O Port 3 10 Standard O Port 1 11 Standard O Port 0 12 S...

Страница 9: ...Provide sensor bus power and actuator power from separate power sources if possible Total current 9 A The total current of all modules may not exceed 9 A even when daisy chaining the actuator supply B...

Страница 10: ...d with cover caps to ensure IP 67 protection rating The baud rate and DeviceNet address are set directly on the BNI DNT using BCD switches The following baud rates 1 are available Switch position 0 12...

Страница 11: ...12 A coded freely configurable female Input Output Combined Inputs Outputs PIN Function Function Input Function Output 1 24 V n c 24V n c 2 Signal 2 n c Signal 2 24V 3 0 V 0 V 0 V 0V 4 Signal 1 24 V S...

Страница 12: ...lated Fieldbus DeviceNet 7 8 5 pin male and female Supply voltage 7 8 4 pin male I O ports M12 A coded 8x female Enclosure rating IP67 only when plugged in and threaded in Weight approx 580 g Operatin...

Страница 13: ...e BNI DNT 104 000 004 This indicator is not present on the BNI DNT 104 000 004 and BNI DNT 202 000 Z005 Each M12 port I O interface is assigned two 2 color LEDs which indicate the configuration or ope...

Страница 14: ...rd inputs 8 standard outputs 2 A Variants 000 no variant Mechanical configuration Z004 Zinc die cast housing Material 1 Balluff housing version Bus connection 7 8 internal thread and 7 8 external thre...

Страница 15: ...Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 IN Word 0 I 15 I 14 I 13 I 12 I 11 I 10 I 9 I 8 I 7 I 6 I 5 I 4 I 3 I 2 I 1 I 0 Word 1 S 15 S 14 S 13 S 12 S 11 S 10 S 9 S 8 S 7 S 6 S 5 S 4...

Страница 16: ...Balluff GmbH Schurwaldstra e 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 857916 E Edition 0708 Subject to modification www balluff com www balluff com...

Отзывы: