Diagnostic data
The BMP reports diagnostic data (events) to the controlling
system (see Tab. 7-15), or the controlling system can read
out the status using the diagnostic parameters.
7.6.1 Diagnostic parameters
Index
Subindex
Parameter
Size
Access
Values
0x0024 (36) 0
Device Status
1 Byte
Read Only
0 = Normal state
2 = Warning
4 = Error
0x0025 (37) 0
Detailed Device
Status
9 Byte
Read Only
Up to 3 active events:
1st byte event type (0 = No event,
0xE4 = Warning, 0xF4 = Error)
2nd and 3rd byte event code (see Sec. 7.6.2)
0x0028 (40) 0
Process Data Input
6 Byte
Read Only
Most recent valid process data (see Sec. 7.2)
Tab. 7-15: Diagnostic parameters
7.6.2 Event list
Event
code
Expression
Meaning
0x8D00
Notification
LIMITED ACCURACY PLUS – The target is located in the detection range, but outside of the
configured measuring range.
0x8D01
Notification
LIMITED ACCURACY MINUS – The target is located in the detection range, but outside of
the configured measuring range.
0x8D02
Warning
OUT OF RANGE PLUS – The target is located outside of the detection range. No valid data
is output. The transmitted process data value is 0×7FFFFFF8 or 2'147'483'640.
0x8D03
Warning
OUT OF RANGE MINUS – The target is located outside of the detection range. No valid data
is output. The transmitted process data value is 0x80000008 or –2'147'483'640.
0x8D04
Error
NO MEASUREMENT DATA – No target detected. No valid data is output. The transferred
process data value is 0×7FFFFFFC or 2147483644.
0x8D06
Warning
MEASUREMENT DATA UNSAFE – The excess gain of the measurement is low. The
application must be reviewed.
0x4210
Warning
DEVICE TEMPERATURE OVERRUN (see section 7.5.6) – The configured upper temperature
threshold is exceeded.
0x4220
Warning
DEVICE TEMPERATURE UNDERRUN (see section 7.5.6) – The configured lower temperature
threshold is not met.
0x4000
Error
TEMPERATURE OVER RUN ERROR – The temperature has exceeded the specified
maximum temperature. The heat source must be removed.
0x5000
Error
HARDWARE FAULT – There is a problem with the device hardware. Restart the BMP by
interrupting the supply. If the event occurs again, the BMP must be replaced.
Tab. 7-16: Event list
7
IO-Link interface (continued)
BMP 01-ZLZPP _ 1A- _ _ _ _ -00 -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System
Содержание BMP 01-ZLZPP 1A 00-P S75 Series
Страница 2: ...www balluff com...
Страница 4: ...www balluff com...
Страница 36: ...www balluff com...
Страница 68: ...www balluff com...
Страница 100: ...www balluff com...
Страница 132: ...www balluff com...
Страница 164: ...www balluff com...
Страница 195: ...BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ S75 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ S4 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _...
Страница 196: ...www balluff com...
Страница 200: ...6 2 1 BMP PLC IO Link BMP 2 2 BMP BMP 2 3 2 4 2 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 203: ...www balluff com 9 C T 4 1 4 2 BMP 4 3 BMP BMP BMP BMP BMP 30 4 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 205: ...www balluff com 11 4 2 30 1 BMP 4 8 4 8 BMP BMP 2 BMP 4 9 3 BMP 4 10 4 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 208: ...14 5 1 1 2 3 BMP BMP 5 2 BMP BMP 5 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 209: ...www balluff com 15 6 1 6 1 1 2 6 2 1 2 6 3 1 2 6 2 16 6 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 226: ...32 11 1 1 2 3 1 2 3 11 1 11 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75 942224 726 ZH 00 000000 L18...
Страница 227: ...BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ S75 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ S4 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _...
Страница 228: ...www balluff com...
Страница 232: ...6 2 1 BMP PLC IO Link Balluff BMP 2 2 BMP BMP 2 3 2 4 2 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 235: ...www balluff com 9 3 C T 4 1 4 2 BMP 1 4 3 BMP BMP BMP BMP N S BMP 30 4 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 237: ...www balluff com 11 4 2 30 1 BMP 4 8 4 8 BMP BMP 2 BMP 4 9 3 BMP 4 10 4 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 240: ...14 5 1 1 2 3 BMP BMP 5 2 BMP BMP 5 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 241: ...www balluff com 15 6 1 6 1 1 2 6 2 1 2 NO NC 6 3 1 2 6 2 16 6 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 258: ...32 11 1 1 2 3 1 2 3 11 1 11 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75 No 942224 726 JA 00 000000 L18...
Страница 259: ...BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ S75 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ S4 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _...
Страница 260: ...www balluff com...
Страница 264: ...6 2 1 BMP IO Link Balluff BMP 2 2 BMP BMP 2 3 2 4 2 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 267: ...www balluff com 9 C T 4 1 4 2 BMP 4 3 BMP BMP BMP BMP BMP 30 4 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 272: ...14 5 1 1 2 3 BMP BMP 5 2 BMP BMP 5 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 273: ...www balluff com 15 6 1 P 6 1 1 2 P 6 2 1 2 P 6 3 1 2 6 2 16 6 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75...
Страница 290: ...32 11 1 1 2 3 1 2 3 P 11 1 11 BMP 01 ZLZPP_1A _ _ _ _ 00 P_ _ P_ _ S4 P_ _ S75 942224 726 RU 00 000000 L18...
Страница 291: ......