40
The information here comprises values at room
temperature in conjunction with magnetic tape
BML TSC-ALCZ-1ZZZ-M_ _ _ with a gap of 0.4 mm over
the magnetic tape (without cover strip).
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
10.1 Accuracy
Position resolution
IO-Link interface
BML SL1-ALZ_-
U_ZZ-_
U1
L-_ _
1 µm
BiSS/SSI interface
BML SL1-ALZ1-
_ _ZZ-ABA
1000/1024 µm
Analog, incremental
real-time signal BML SL1-
ALZ0-U1ZZ-
A
U1L
Period 2 mm
Repeat accuracy
< 1 μm
Hysteresis
≤ 1 μm
Max. non-linearity of sensor
head
±5 μm
Linearity deviation
of entire system (sensor
head + magnetic tape)
Temperature coefficient of
the entire system
10.5 ppm/K
Movement speed
Max. 10 m/s
10.2 Ambient conditions
Operating temperature
BML-ALZ
0
....
BML-ALZ
1
....
–10 °C…+70 °C
–20 °C…+70 °C
Storage temperature for
sensor head
–25 °C…+85 °C
Cable temperature rating
–25 °C…+80 °C
Shock rating
Continuous shock
per EN 60068-2-27
2)
100 g/6 ms
150 g/2 ms
Vibration load per
EN 60068-2-6
2)
20 g, 10…2000 Hz
Noise per EN 60068-2-64
2)
20 g, 5…2000 Hz
Degree of protection per
IEC 60529 (with
screwed-on connector)
IP67
External magnetic fields
– < 30 mT (to avoid
permanent damage)
– < 1 mT (to avoid
influencing the
measurement)
Relative humidity
90% RH, condensation not
permitted
10.3 Power supply
Supply voltage
3)
BML SL1…
…-ALZ_-U_ZZ-_U1
L
-…
…-ALZ1-__ZZ-ABA
1
-…
…-ALZ1-__ZZ-ABA
5
-…
18…30 V
10…30 V
5 V ±10 %
Current draw
4)
at 24 V
5)
at 5 V
5)
70 mA
170 mA
Power consumption
≤ 1.4 W
Polarity reversal protection
No
Overvoltage protection
No
Dielectric strength (GND to
housing)
500 V DC
Switch-on delay (system
ready) after applying supply
voltage
100 ms
1)
For
: Use in enclosed spaces and up to a height of 2000 m above
sea level.
2)
) Individual specifications as per Balluff factory standard, resonant
frequencies excluded
3)
For
: The sensor head must be externally connected via a limited-
energy circuit as defined in UL 61010-1 a low-power source as defined in
UL 60950-1 or a Class 2 power supply as defined in UL 1310 or
UL 1585.
4)
Without controller current draw
5)
Supply voltage
1)
10
Technical data
BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
english
Содержание BML SL1-ALZ-ZZ Series
Страница 2: ...www balluff com...
Страница 3: ...deutsch Betriebsanleitung BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Страница 4: ...www balluff com...
Страница 53: ...english User s Guide BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Страница 54: ...www balluff com...
Страница 103: ...fran ais Notice d utilisation BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Страница 104: ...www balluff com...
Страница 153: ...italiano Manuale d uso BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Страница 154: ...www balluff com...
Страница 203: ...espa ol Manual de instrucciones BML SL1 ALZ_ _ _ZZ _ _ _ _ _ _ _ _...
Страница 204: ...www balluff com...
Страница 253: ......