12
4.3.4 Working ranges, angles, distances, tolerances
and measuring accuracy – Curved application
Rotating application is only possible using
sensors in the BML SL1-ALZ
1
-… series.
Fig. 4-7:
Z
X
Z
Tangential point
–Pitch
+Pitch
Tolerances for applications with curved tape
Diameter
2000 mm
1000 mm
400 mm
Mechanical tolerances
Z
(air gap sensor/magnetic tape)
≤ 1.0 mm
≤ 0.6 mm
≤ 0.1 mm
Z
(air gap between sensor/magnetic
tape with cover strip)
0.85 mm
0.45 mm
–
Y
(lateral offset)
±0.5 mm
X
(tangential offset)
32.5 mm ±1 mm
Pitch
±0.5°
Yaw
±1°
Roll
±0.5°
Tab. 4-3: Function ranges, angles, distances, and tolerances