www.balluff.com
5
1.1
Validity
This guide describes the construction, function and
installation options for the BML absolute magnetic encoder
system. It applies to the following models (see Type code
–
BML SL1-ALZ0-U1ZZ - _ U1L- S284/S4/KA _ _
–
BML SL1-ALZ1-UE/MZZ- _ U1L -S284/S4/KA _ _
The guide is intended for qualified technical personnel.
Read this guide before installing and operating the
magnetic encoder system.
For additional information about the interfaces
please refer to the document
Interfaces for
BML Magnetic Encoder
.
1.2
Symbols and conventions
Individual
actions
are indicated by a preceding triangle.
►
Instruction 1
Action sequences
are numbered consecutively:
1.
Instruction 1
2.
Instruction 2
Numbers
unless otherwise indicated are decimals (e.g.
23). Hexadecimal numbers are represented with a
preceding 0x (e.g. 0x12AB).
Note, tip
This symbol indicates general notes.
1.3
Scope of delivery
– Sensor head BML SL1
– Condensed guide
Magnets are available in various models and
must be ordered separately (see Accessories on
1.4
Approvals and markings
UL approval
File no.
E227256
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
The transducer meets the requirements of the following
product standard:
– EN 61326-2-3 (noise immunity and emission)
Emission tests:
– RF emission
EN 55011
Noise immunity tests:
– Static electricity (ESD)
EN 61000-4-2
Severity level 4
– Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
– Electrical fast transients (burst)
EN 61000-4-4
Severity level 3
– Surge
EN 61000-4-5
Severity level 2
– Conducted interference induced by
high-frequency fields
EN 61000-4-6
Severity level 3
– Magnetic fields
EN 61000-4-8
Severity level 5
More detailed information on the guidelines,
approvals, and standards is included in the
declaration of conformity.
1.5
Abbreviations
1Vpp
Incremental Sin/Cos Interface
BML
Balluff Linear Magnetic Encoder System
CRC
Cyclic Redundancy Check
IODD
IO Device Description
MDC
Measurement Data Channel
PD
Process Data
PDV
Process Data Variable
SIO
Standard Input Output
SSC
Switching Signal Channel
1
Notes to the user
BML SL1-ALZ _ -U_ ZZ- _ U1L - _ _ _ _
Absolute magnetic encoder system
english
Содержание BML SL1-ALZ-U-ZZ-U1L Series
Страница 2: ...www balluff com...
Страница 3: ...deutsch Betriebsanleitung BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Страница 4: ...www balluff com...
Страница 52: ......
Страница 53: ...english User s Guide BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Страница 54: ...www balluff com...
Страница 102: ......
Страница 103: ...fran ais Notice d utilisation BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Страница 104: ...www balluff com...
Страница 152: ......
Страница 153: ...italiano Manuale d uso BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Страница 154: ...www balluff com...
Страница 202: ......
Страница 203: ...espa ol Manual de instrucciones BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Страница 204: ...www balluff com...