17
english
6.4.3 System command (Index 0x02)
This allows functions such as signal normalization and reset to be called.
Index 0x02 (1 Byte length) :
Value (decimal)
Value (Hex)
Function
130
0x82
Restore factory default settings
160
0xA0
Signal normalize (see chap.
5.2
)
6.4.4 Parameter data
The BLA ist fully configurable through the parameter data.
a) Selection of the output function
Index 0x40 :
Sub-
index
(hex)
Object name
Length
(Byte)
Range
(dec)
Default
value
Access Comments
0
Main Parameters
16
1
Analog Output 1 Mode 1
0 - 8
1
R/W
see below
2
Analog Output 2 Mode 1
0 - 8
3
R/W
see below
3
Digital Output Mode
1
0 - 10
5
R/W
see below
4
Digital Object
Detection Tolerance
1
0 - 20
2
R/W
Tolerance in object recognition:
0.1 - 2.0 mm
5
Digital Object Counting
Size
1
0 - 243
0
R/W
Object size in object counting:
0 - 24.3 mm
6
Digital Object Counting
Tolerance
1
0 - 243
0
R/W
Tolerance object size for object counting:
0 - 24.3 mm
7
(not used)
8
Range Enable
1
0 - 1
0
R/W
Blanking: 0 - Disable, 1 - Enable
9
Range Left
2
0 - 487
0
R/W
Hidden area on the left: 0 - 48.7 mm
A
Range Right
2
0 - 487
0
R/W
Hidden area on the right: 0 - 48.7 mm
B
Average AOut1
2
1 - 1024 1
R/W
Averaging analog value 1 over n cycles
(1 = no averaging)
C
Average AOut2
2
1 - 1024 1
R/W
Averaging analog value 2 over n cycles
(1 = no averaging)
•
IO-link interface (continued)
6
BLA 50A-002-S4
Balluff Light Array
BLA 50A-002-S4
Содержание BLA 50A-002-S4
Страница 1: ...deutsch Betriebsanleitung english User s guide BLA 50A 002 S4 Balluff Light Array...
Страница 2: ...www balluff com...
Страница 3: ...deutsch BLA 50A 002 S4 Balluff Light Array Betriebsanleitung...
Страница 23: ...english BLA 50A 002 S4 Balluff Light Array User s Guide...
Страница 43: ......