background image

 

www.balluff.com 

   

   

 

2

 

Safety 

 

 

Important! 

Before commissioning, carefully read the operating manual. 

 

2.1.

 

Proper Use 

 

The device is designed to replace a plug connection in order to ensure contact-free energy 
transmission.The system must not be used in applications in which the safety of persons is 
dependent on the function of the device. 
Warranty and liability claims against the manufacturer are rendered void by: 

  Unauthorized tampering 

  Improper use 

  Use, installation or handling contrary to the instructions provided in this operating 

manual 

 

2.2.

 

Authorized 
Personnel 

  Installation and commissioning may only be performed by trained specialist personnel. 

 

2.3.

 

Obligations of the 
Operating 
Company 

 

The operating company must ensure that the locally applicable safety regulations are 
observed.The device corresponds to EMC Class A and can cause radio interference. The 
operating company must take appropriate precautions to prevent radio interference. 

The device may only be used with an approved power supply. (see "Technical Data"). Only 
approved cables may be used. 

 

2.4.

 

Malfunctions 

  In the event of defects and device malfunctions that cannot be rectified, the device must be 

taken out of operation and protected against unauthorized use. 

 

2.5.

 

Meaning of the 
Warning Notices 

 

The warning notices in this guide and the measures described for avoiding dangers must be 
observed.The warning notices contain the following signal words that indicate the severity of 
the danger: 

 

Danger

:  

Indicates an immediate danger that will result in a severe injury or death of persons if not 
observed. 

 

Warning

Indicates a potential danger that may result in a severe injury or death of persons if not 
observed. 

 

Caution

Indicates a potential danger that may result in light injury to persons or damage to 
property if not avoided. 

 

Attention

Indicates a situation that may result in property damage if not avoided. 
 

When working with this product, the following warning notices apply: 

 

 

 

Caution! 

Risk of burning on hot surfaces! 
The active surface heats up even under normal operating conditions. 

Keep away hands and objects from the active surface. 

Avoid contact of metal objects on the active surface. Fire hazard 

 

2.6.

 

Certification 

 

With the CE marking, we confirm that our products meet the requirements of EC 
directives 2004/108/EC (EMC) and the EMC law. 
In our EMC laboratory, which is accredited by DATech for testing electromagnetic 
compatibility, evidence has been provided that the Balluff products satisfy the EMC 
requirements of the generic standards:  

EN 61000-6-4 (Interference emission) and 

EN 61000-6-2 (Immunity to interference) 

Содержание BIC 1I3-P2A50-M30MI3-SM4ACA

Страница 1: ...Uni Standard 8 way 500 mA IP67 User s Guide...

Страница 2: ...4 3 2 Function 4 3 3 Features Advantages 4 3 4 Display 4 4 Indication 5 5 Installation and Connection 6 5 1 Mutual Interference 6 5 2 Installation in Metal 6 5 3 Angle Offset 6 5 4 Connection 7 6 Tec...

Страница 3: ...y 1 Entry 2 Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Syntax Numbers De...

Страница 4: ...otected against unauthorized use 2 5 Meaning of the Warning Notices The warning notices in this guide and the measures described for avoiding dangers must be observed The warning notices contain the f...

Страница 5: ...sors are wired to the remote The remote is only inductively coupled to the base however The base transmits the energy for the sensors to the remote The signal from the sensors is transmitted to the ba...

Страница 6: ...etween base and remote no data transmission Yellow static Connection between base and remote OK data transmission secured Remote indicators Indicators Function Green static Supply voltage OK Green fla...

Страница 7: ...CA 100 5 2 Installation in Metal Attention Device damage due to induction effects Metallic objects on the coil cap cause the objects to be heated Install the components so that no metallic objects can...

Страница 8: ...nections base The base is wired via a type 2 characteristic acc to IEC 61131 2 Power M12 12 pin male plug PIN Signal Meaning 1 24 V Input voltage 2 GND Ground 3 Signal 1 Signal 1 4 Signal 2 Signal 2 5...

Страница 9: ...per IEC 60529 IP 67 only in plugged in and screwed down state Connection type M12 A coded Dimensions D x L in mm M30 X 100 Weight Approx 160 g Tightening torque 70 Nm 6 3 Operating Conditions Base Tra...

Страница 10: ...d screwed down state Connection type M12 A coded Cable PUR Dimensions D x L in mm M30 X 100 Weight Approx 160 g Tightening torque 70 Nm 7 3 Operating Conditions Remote Transmission distance 1 5 mm Amb...

Страница 11: ...es 8 1 Connectors PUR BCC M41C 0000 1A 049 PX0C14 XXX For base XXX cable length PVC BCC M41C 0000 1A 049 VX8C14 XXX For base XXX cable length PUR BCC M41C 0000 2A 049 PX0C14 XXX For remote XXX cable l...

Страница 12: ...y PNP variant 24 V power class 500 mA Housing shape M30x1 5 Housing material M brass and length SM4ACA Connector M12 axial Number of pins and coding BPX0C Cablel PUR Number of wire Cable lenght Pig Ta...

Страница 13: ...Balluff Inductive Coupler Base BIC 1I3 P2A50 M30MI3 SM4ACA und Remote BIC 2I3 P2A50 M30MI3 SM4ACA Remote BIC 2I3 P2A50 M30MI3 BPX0C 002 M4CA www balluff com 12 Note...

Страница 14: ...www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Deutschland Tel 07158 173 0 Fax 07158 5010 balluff balluff de Nr 885659 726 E 04 130719 Edition A21 Replaces Edition K18 Subject...

Отзывы: