background image

Model: 

 

 

 

 

 

 

 

 

BF-IDM32 

 

 

Operating Guide  

RFID Reader  

 

Setup and Operation 

 
For operation of BF-IDM32 Readers a IO-Link Master device is needed. The Master is used as 
gateway between higher level controllers and RFID Reader. 
 

Status Indicators 

 
The device will show its status using the 2 LEDs at the corners of the housing. In normal 
operation state the meaning of these lights are as follows: 
 

► 

Green light "Power" indicates that the device is connected to the processor unit and ready to 

operate. 

► 

Orange light "Tag present" indicates that a RFID tag has been detected in front of the 

transceiver coil. 
 

Electrical Data 

 
Operating voltage (nominal) 

+24 V DC 

Current draw (at +24 V DC) 

≤ 200 mA 

Operating Frequency 

13.56 MHz 

Active principle 

Magnetic field 

Transmit power 

Class 5 

 

Mechanical Data 
 

Housing Material 

Metal / ABS-GF16 / PBT / PA12-GF30 

Weight max. 

400g 

Ambient temperature 

0…+70°C 

 

Содержание BF-IDM32

Страница 1: ... 25 Distrito Industrial CEP 13280 000 Vinhedo SP Canada Balluff Canada Inc 2840 Argentia Road Unit 2 Mississauga Ontario L5N 8G4 China Balluff Shanghai Trading Co Ltd No 800 Chengshan Rd 8F Building A Yunding International Commercial Plaza 200125 Pudong Shanghai Japan Balluff Co Ltd Aqua Hakusan Bldg 9F 1 13 7 Hakusan Bunkyo ku Tokyo 113 0001 Mexico Balluff de México S A de C V Anillo Vial II Fray...

Страница 2: ... si le brouillage est susceptible d en compromettre le fonctionnement Changes or modifications not expressly approved by the party responsible for compliance voids the user s authority to operate this equipment Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable pro...

Страница 3: ...FID Reader Purpose of the Device The BF IDM32 RFID Reader is intended to read and write ISO15693 compliant data carriers via magnetic field communication Variability BF IDM32 RFID Readers are available in different housings and shapes ...

Страница 4: ...nsure reliable operation in strong EMC environments it is recommended to connect metal housings or dedicated functional ground pins directly to installations ground The ground connection should be short and stable Depending on the installation situation an indirect ground connection using a RC combination may be required For further notes concerning the installation of the processor unit please re...

Страница 5: ... electrical or magnetic fields in the close environment may influence the RFID Reader Precise information concerning clear zones and distances are available on request For BF IDM32 Readers are available in different housings respectively shapes different types of installation may be considered a Direct In Hole mounting Example Picture 2 Direct In Hole mounting Example b Direct On Wall mounting Exa...

Страница 6: ...Model BF IDM32 Operating Guide RFID Reader c Indirect On Wall mounting using metal holder Example Picture 3 Indirect On Wall mounting using metal holder Example ...

Страница 7: ...ion state the meaning of these lights are as follows Green light Power indicates that the device is connected to the processor unit and ready to operate Orange light Tag present indicates that a RFID tag has been detected in front of the transceiver coil Electrical Data Operating voltage nominal 24 V DC Current draw at 24 V DC 200 mA Operating Frequency 13 56 MHz Active principle Magnetic field Tr...

Отзывы: