Intended use

The inductive proximity switch is for use as contactless wearout-free limit switch in industrial control systems. 

The inductive proximity switch may only be connected to electronic evaluation devices type BAE SA-XE-

***

-

XR-SA39. It can be mounted inside gas-hazardous areas that require equipment of category Class I Div. 1 

(Zone 0 or Zone 1), or dust-hazardous areas that require equipment of category Class II/III Div. 1 (Zone 20 

or Zone 21). If there are additional regulations for the particular design regarding the installation, they must 

be observed as well.

Safety instructions

• 

The safety of any system incorporating the equipment is the responsibility of the assembler of the system.

•  If the device is not mounted and operated as described here, the protection provided by the

  equipment may be impaired.

•  Only professionals with sufficient knowledge are allowed to install and operate the device.

•  Prior to installation disconnect the system from power supply.

•  

Use the specified tightening torque for the nut from the table (Installation) during assembly.

•  Comply with the provisions of the instruction manual.

•  Comply with the national regulations and installation provisions.

•  Absolutely abide by the specific conditions.

Installation and operation

•  Make sure that the device is used only in the area of application corresponding to its Ex marking.

•  Do not modify the device (e.g. painting).

•  Make sure that the housing of the proximity switch has electrical contact to a grounded metal structure.

•  If necessary, use wire type that has a temperature rating ≥ Ta.

•  Install cables according to the applicable regulations and protect them from damage.

•  The device complies with the EMC requirements for proximity switches according to

  CAN/CSA-C22.2 No 60947-5-2.

•  Cables longer than 30 m can require additional EMC measures.

•  Datasheet, certificate and MTTF values are available on request.

Maintenance, repairs and trouble-shooting

•  Do not modify or repair the device – its approval will expire. Contact the manufacturer for any problems.

•  Prevent dust from covering the device, i.e by regulary cleaning with a damp cloth.

Conditions of Acceptability

•  The instruction manual must be consulted for technical data which are not included in the Ex-marking 

 

  of the sensor (maximum values, ambient temperature ranges, manufacturer address).

• 

By using types of this device with plastic surface bigger than 400 mm² (gas) or 500 mm² (dust),

  therefore the equipment shall not be installed in a location where the external conditions are

  conductive to the build-up of electrostatic charge on such surfaces.

  When indicated, periodic cleaning should be done by damp cloth.

• 

The device must be protected against UV light.

• 

End-user shall ensure proper earthing of the device upon installation.

Содержание BES M30EH2-GNX15F-BT02-X03

Страница 1: ...english User s guide fran ais Notice d utilisation BES M30EH2 GNX15F BT02 X03...

Страница 2: ...nstallation provisions Absolutely abide by the specific conditions Installation and operation Make sure that the device is used only in the area of application corresponding to its Ex marking Do not m...

Страница 3: ...Effective internal inductivity Li 1 2 mH Electrostatic chargeable plastic housing With reference to group II gas 573 mm With reference to group III dust 1421 mm Housing material AISI 316 Ti PTFE PVDF...

Страница 4: ...rounded metal frame Type max torque M12x1 M18x1 M30x1 5 10 Nm 25 Nm 40 Nm 52 35 M30x1 5 36 15 10 No 947390 726 EN 01 131212 E21 Subject to modification Replaces E20 BA S36101 GB 2021 18 Instruction ma...

Страница 5: ...and national regulations List of applicable standards CAN CSA C22 2 No 60947 5 2 14 CAN CSA C22 2 No 60079 0 15 CAN CSA C22 2 No 60079 11 14 UL 60947 5 2 Third Edition ANSI UL 60079 0 13 ANSI UL 60079...

Страница 6: ...articuli res Installation et mise en service S assurer que l appareil est utilis uniquement dans une zone correspondant son marquage Ex Ne pas proc der des modifications sur l appareil par exemple le...

Страница 7: ...iques susceptibles d tre charg es d lectricit statique Consid ration conform ment au groupe II gaz 573 mm Consid ration conform ment au groupe III poussi re 1421 mm Mat riaux du bo tier acier inoxydab...

Страница 8: ...sion cadre de montage m tallique mis la terre de mani re standard type couple de tension max M12x1 M18x1 M30x1 5 10 Nm 25 Nm 40 Nm 52 35 M30x1 5 36 15 10 N 947390 726 FR 01 131212 E21 Sous r serve de...

Страница 9: ...les prescriptions nationales Liste des normes applicables CAN CSA C22 2 No 60947 5 2 14 CAN CSA C22 2 No 60079 0 15 CAN CSA C22 2 No 60079 11 14 UL 60947 5 2 Third Edition ANSI UL 60079 0 13 ANSI UL 6...

Страница 10: ...ngshan Rd 8F Building A Yunding International Commercial Plaza 200125 Pudong Shanghai Phone 86 400 820 0016 Fax 86 400 920 2622 service cn balluff com cn DACH Service Center Germany Balluff GmbH Schur...

Отзывы: