Balluff BDD-UM 3023 Скачать руководство пользователя страница 5

1.

Discription

The  di gi tal  pa nel  me ter  mo del 

BDD-UM 3023

 is an uni ver sal in stru ment for mea -

su ring  ana log  in put  si gnals  li sted  be low:

• Vol ta ge  0 - 10 V

• Cur rent  0 - 20 mA / 4 - 20 mA

Stan dard  Hard ware

• 4 func tion but tons on the  front si de

Stan dard  Soft ware

• Sca ling

• Ta ring

• Free set ting of de ci mal point

• Dis play  test

2.

Safety instructions

When de li vered the in tru ment has been te sted to meet all func ti ons descri bed.
Be fo re  in stal ling  the  in stru ment  plea se  read  the  moun ting  and  ser vicing  in struc ti -
ons. We have no lia bi li ty or re spon si bi li ty to cu sto mer or any other per son or en ti ty
with re spect to any liabli ty, loss or da ma ge cau sed or al le ged to be cau sed di rectly 
or in di rectly by equip ment or soft ware sold or fur nis hed by us. Read the in stal la ti -
on  in struc tion  ca re ful ly.  No  lia bi li ty  will  be  as su med  for  any  da ma ge  cau sed  by  im -
pro per  in stal la ti on.
In spect the in stru ment mo du le car ton for ob vious da ma ge. Be shu re the re are no
ship ping and hand ling da mages on the mo du le be fo re pro ces sing. Do not apply
po wer to the in stru ment if it has da mages.
The war ran ty does not apply to de fects re sul ting from ac tion of buy er, such as
mis hand ling,  im pro per  in ter facing,  ope ra ti on  out si de  of  de sign  li mits,  im pro per  re -
pair  or  un au tho ri zed  mo di fi ca tions.

4

1.  Discription

Содержание BDD-UM 3023

Страница 1: ...english User s Guide BDD UM 3023...

Страница 2: ...efective material and workmanship for a period of two 2 years from date of delivery If it is necessary to return the product to us the sender is responsible for shipping charges freight insurance and...

Страница 3: ...ns 6 4 1 General Instructions 6 4 2 Hints against noisy enviroment 7 4 3 Connection and pin assignment 7 4 4 Connection of input signals 8 4 4 1 Input voltage 0 10 V 8 4 4 2 Input current 0 20 mA 4 20...

Страница 4: ...7 1 1 Scaling the display range 12 7 2 Tare function 13 7 3 Display test 13 7 4 Programming quick reference 13 8 Technical specifications 14 3...

Страница 5: ...lity to customer or any other person or entity with respect to any liablity loss or damage caused or alleged to be caused directly or indirectly by equipment or software sold or furnished by us Read t...

Страница 6: ...ion 3 Mounting 3 1 Place of operation Attention must be payed to the protection against humidity dust and high tempe ratures at the place of operation 3 2 Panel mounting 3 2 1 Panel for switch board I...

Страница 7: ...tages applied Cords must be provided with sleeves Attention must be paid that the power supply voltage applied will agree with voltage noticed at the Type plate It is important to ensure a careful gro...

Страница 8: ...advisable To use shielded cables The wiring of shields and ground 0V should be star shaped The distance to interference sources should be as long as possi ble If necessary protective screen or metal e...

Страница 9: ...3 Signal ground 6 Supply voltage 4 4 Connection of input signals 4 4 1 Input voltage 0 10 V 4 4 2 Input current 0 20 mA 4 20 mA 4 5 Connection of power supply voltage 8 4 Electrical connections 3 0 V...

Страница 10: ...onfiguration by programming Attention When the instrument is built in a machine and the custo mer wants to change the configuration attention must be paid that no damage will occur to the machine 6 Pr...

Страница 11: ...y the buttons on the front Push button Function P button Selection of parameter button Increase of number of parameter parameter button Decrease of number of parameter parameter button select the disp...

Страница 12: ...on Confirm the parameter by pressing the P button The display shows the programming level and the number of the parameter e g 0 04 parameter 4 7 1 Programming level for configuration 0 00 Param Descri...

Страница 13: ...input current 1mA or 3mA the display range exceeds the possible minimum 999 the parameter P0 03 has the value3 decimal point after the first decade X XXX in this case is the display of negative value...

Страница 14: ...0 04 had to be set to 1 Erase the tare value push the button for ca 3 seconds After this reset the untared value is dis played 7 3 Display test Activating the display test will drive all segments of...

Страница 15: ...n at negative Values Operation keyboard design front membrane with push buttons Power supply 24 V 20 DC isolated power consumption max 65 mA Case 96 x 48 x 60 mm depth 72 mm incl screw terminal protec...

Страница 16: ...41042 Phone 859 727 2200 Toll free 1 800 543 8390 Fax 859 727 4823 technicalsupport balluff com CN Service Center China Balluff Shanghai trading Co ltd Room 1006 Pujian Rd 145 Shanghai 200127 P R Chin...