17
5.2.
Encoder Properties
SAMPLING TIME (S)
Period duration between two init pulses (in milliseconds). Corresponds to the time after a new measurement
is started and directly affects the reaction time of the device.
0
00.200
Minimum measurement time
04.000
Default value
1
16.000
Maximum measurement time
VELOCITY (M/S)
Waveguide velocity of the encoder (in m/s).
0001.00
Smallest value
2800.00
Default value
9999.99
Highest value
OFFSET
In the case of a “Reset/Set Value” command (via keyboard command, control input or PC user interface) the
current position of the encoder is transferred to the parameter "Offset".
-99999999
Smallest value
0
Default value
99999999
Highest value
DIRECTION
Definition of the direction of rotation forward / backward
0
FORWARD
Forward
1
REVERSE
Backwards
ENCODER SUPPLY
This parameter defines the output voltage of the auxiliary voltage output (Aux. Out).
0
24VDC
SUPPLY
24 VDC Encoder supply
1
5VDC
SUPPLY
5
VDC Encoder supply
Содержание BAE010M