14
5.1.
General Menu
OPERATIONAL MODE
This parameter determines which measurement function (mode) the device should run.
0
DISTANCE
Distance measurement
1
ANGLE
Angle measurement (display in degrees)
LENGHT PER REVOLUTION
(
in millimeters)
This is the distance travelled (circumference) per 360 degrees and is indicated in "mm".
00000.100
Smallest value
01000.000
Default value
99999.999
Highest value
FACTOR
This parameter defines the factor.
-99999999
Smallest value
1
Default value
99999999
Highest value
DIVIDER
This parameter defines the divider.
-99999999
Smallest value
1
Default value
99999999
Highest value
ADDITIVE VALUE
This parameter defines the additive constant.
-99999999
Smallest value
0
Default value
99999999
Highest value
DECIMAL POINT
This value defines the position of the decimal point. This is only a decimal point that can be graphically
switched. This does not affect the two scaling factors FACTOR and DIVIDER.
0
NO
No decimal point
1
0000000.0
Decimal point at the specified position
2
000000.00
Decimal point at the specified position
3
00000.000
Decimal point at the specified position
4
0000.0000
Decimal point at the specified position
5
000.00000
Decimal point at the specified position
6
00.000000
Decimal point at the specified position
7
0.0000000
Decimal point at the specified position