31
5.15 Analog Out Menu
This menu defines the basic settings of the analog output. This function is only available for
BDD 750-_ _ _ _-103-
…
ANALOG SOURCE
This parameter defines the reference source for the Analog Output
0 INPUT 1
the reference source is input 1
1 INPUT 2
the reference source is input 1
2 LINKAGE 1
– 2
the reference source is the result of the linking of input1 and input 2
3 INPUT 1 TOTAL
the reference source is input 1 with totalization
4 INPUT 2 TOTAL
the reference source is input 1 with totalization
5
LINKAGE TOTAL
the reference source is the result of the linking of input1 and input 2
with totalization
8 MINIMUM VALUE 1
minimum value, the reference source is input 1
9 MAXIMUM VALUE 1
maximum value, he reference source is input 1
10 MINIMUM VALUE 2
minimum value, the reference source is input 2
11 MAXIMUM VALUE 2
maximum value, he reference source is input 2
The totalization depends on the operation mode. See chart in chapter IN 1 Totalization.
ANALOG FORMAT
This parameter defines the output characteristics. The analogue output is proportional to the
display value.
With setting ANALOG FORMAT (-
10 … +10 V) in MODE COUNTER the polarity of the analog
output depends on the polarity of the display value.
0
-
10…10V
-
10 … +10 V
1
0…20MA
0 … 20 mA
2
4…20MA
4 … 20 mA
ANALOG START
This parameter defines the start value of the analog conversion. This start value is corresponding
to the display value for an analog output of 0 V or 0/4 mA.
-99999999
Smallest start value
0
Default value
+99999999
Highest start value
ANALOG END
This parameter defines the end value of the analog conversion. This end value is corresponding
to the display value for an analog output of (+/-) 10 V or 20mA.
-99999999
Smallest end value
10000
Default Wert
+99999999
Highest end value
Содержание BAE010H
Страница 1: ...Touch Display BDD 750 _A User s Guide English ...
Страница 48: ...48 6 5 Dimensions Dimension in mm inch ...
Страница 50: ...50 ...
Страница 51: ...51 ...