14
english
7
Operating mode (continued)
Analog sensors
SA
If the analog output is used as a voltage interface
(0…10 V), the load resistance (Q towards GND)
must be between 1 kΩ and 10 kΩ. If the output is
used as a current interface, the shunt resistance
(Q towards GND) must be between 0 and 400 Ω.
The value actually displayed (4 digits) depends on
the connected sensor. It is a continuous analog
value and usually not linear.
Display Configuration
10U
Setting
as voltage output (0…10 V)
20 mA
Setting
as current output (4…20 mA)
Tab. 7-6: Adjusting analog sensors
7.6.3 Adjusting the switching mode
(only in operating mode switching)
Mod
After the switching mode is selected, the selection
for adjusting the switchpoints returns to the main
menu
t S
.
For examples of typical teach-in processes, see the figures
Standard switching mode
St d
The system generally works with only one defined switch-
point: object or fill level (half of active surface covered with
medium) reliably detected. If the measurement falls below
the switchpoint by a small amount, the output switches to
off
.
Fig. 7-4:
Sensor value
SP1
tS: SP1
tS: SP2
Output
On
Off
Standard switching mode
2-point switching
2Pt
Separate teach-in of switch-on point (menu 2 SP1) and
switch-off point (menu 2 SP2). The switchpoints can be set
very wide apart, e.g. to control a min. and max. (fill level).
Fig. 7-5:
Sensor value
SP1
SP2
tS: SP2
tS: SP1
Output
On
Off
2-point switching
Window function
Wi n
The system is only actuated in the range between the set
switchpoints.
Fig. 7-6:
Sensor value
SP1
SP2
tS: SP2
tS: SP1
Output
On
Off
Window function
Dynamic operation
dyn
The system responds only to adequately fast changes to
measurements (moved objects). Static conditions (back-
ground) are permanently eliminated with a long time cons-
tant (output off).
No additional adjustments are necessary.
BAE SA-CS-026-YP-BP02 / BAE SA-CS-026-YP-BP00,3-GS04
Comfort Sensor Amplifier
Содержание BAE SA-CS-026-YP-BP02
Страница 1: ...BAE SA CS 026 YP BP02 BAE SA CS 026 YP BP00 3 GS04 deutsch Betriebsanleitung english User s guide...
Страница 2: ...www balluff com...
Страница 3: ...BAE SA CS 026 YP BP02 BAE SA CS 026 YP BP00 3 GS04 Betriebsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 26: ......
Страница 27: ...BAE SA CS 026 YP BP02 BAE SA CS 026 YP BP00 3 GS04 User s Guide english...
Страница 28: ...www balluff com...