7.CONTROL MODE
Other functions
1. Flap control
1.1 Press the FLAP button on the remote controller continuously, the flap will alternate within the
following eight positions: Auto, fixed (including the six positions of the flap from top to
1,2,3,4,5,6) and swing.
1.2 Auto: During the heating mode, the flap is set at position 5; during the cooling and
dehumidification mode, the flap is at position 2; during the fan mode, it is at position 2.
1.3 Fixed: The position of the flap is fixed at a certain position by the remote controller.
1.4 Scanning: During cooling and fan mode, the flap sways among positions 1—4; during heating
mode, the flap sways between positions 3—6.
1.5 The default mode is Auto.
1.6 When first turned on or turned off, the flap will turn to the furthermost positions to ensure well
closing of the flap. When started, the flap will turn to the furthermost positions. After the grille
is completely closed, it will turn to the setting position.
2. Man-machine communication
2.1 The indoor controller has two temperature sensors to detect the room temperature: one in the
controller and the other at the air inlet of indoor unit. The default airflow setting depends on
that detected by the remote controller. The remote controller detects room temperature once
every 20 seconds and transmits signals once every 3 minutes or when the detected
temperature is not the same. If the indoor controller cannot receive signals for more than 10
minutes, it will automatically start the temperature sensor
at the air inlet of indoor unit.
Meanwhile, the man-machine communication symbol on the screen will go off.
2.2 The man-machine communication mode cannot be cancelled by the switching-on and off
operations. When the machine is switched off, the man-machine communication symbol will
remain on.
2.3 When the machine is turned on, the man-machine communication symbol will appear. When
the air conditioner is started by the switch button of indoor unit, the man-machine
communication symbol will go off.
3. Timing on and off
3.1 Timing On: when the timing-on function is set by the remote controller, the timing-on function
of the air conditioner is activated and the timer symbol lights up. When the setting time
arrives, the machine starts with the setting mode after a signal from the remote controller is
received. If no signal is received at the setting time, the machine will run by automatic
settings. At the same time, the man-machine communication symbol goes off.
3.2 Timing Off: when the timing-off function is set by the remote controller, the timing-off
function of the air conditioner is activated and the timer symbol lights up. When the setting
time arrives, the machine shuts off after a signal from the remote controller is received. If no
signal is received at the setting time, the machine will automatically shut off. At the same
time, the man-machine communication symbol goes off.
3.3 The timing mode cannot be cancelled by the switching-on and off operations. When the
machine is switched off, the timer symbol remains on.