background image

4

Note: Each mode and relevant function will be further specified in following pages. 

SLEEP

FAN

TIMER

SWING

ON/OFF

MODE

MID

SWING

AUTO

DRY
FAN
HEAT

COOL

FEEL

SLEEP TIMER ON

HIGH

LOW

TMIER OFF

The remote controller transmits signals  to the system.

Remote controller

1

2

4

3

5

6

7

8

8

4

MODE  button

FAN SPEED control button

UP button (TOO COOL button)

DOWN button (TOO WARM button) 

ON/OFF button

SLEEP  button

VANE control button

 TIMER button

Used to select the type of operation mode:  Feel, 
Cooling, Dry, Fan and Heating(Only for Heat Pump).
 

Used to select the indoor fan motor speed:
 Auto, High, Mid and Low. 

Used to increase the set room temperature

 and time.

Used to decrease the set room temperature
and time. 

Used to set or cancel sleep mode operation. 

Used to start and stop operation 
when pressed.  

Used to adjust airflow direction.

Used to select TIMER operation.

Remote controller

6

2

5

3

7

1

1

1

 Air Conditioner Service Manual

Operation Details

Remote Control

The remote  controller is  not  preset

ted

  as Cooling  Only Air Conditioner  or Heat  Pump by  manufacturer.

Each time after the remote controller replace batteries or is energized, the arrowhead will flashes on the front of 

Heat

or 

Cool

on LCD of the remote controller.

User can preset the remote controller type depending on the air conditioner type you have purchased as 
follows:
Press any button when the arrowhead flashes on the front of 

Cool 

, Cooling Only is set.

Press any button when the arrowhead flashes on the front of 

 Heat

, Heat Pump is set.

If you don

t press any button within 10 seconds, the remote controller is preset as Heat Pump automatically.

Note :

If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat Pump, it 
doesn

t bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you preset the 

remote controller  as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.

Содержание BSZ-30H

Страница 1: ...TED SPLIT TYPE AIR CONDITIONERS CONTENTS 1 IMPORTANT NOTICE 2 2 TECHNICAL SPECIFICATION 3 3 OPERATION DETAILS 4 4 WIRING DIAGRAM 12 5 EXPLOSION VIEW 13 6 PARTS LIST 15 Models BSZ 30H SERVICE MANUAL No...

Страница 2: ...information nor can it assume any liability in connection with its use The information specifications and parameter are subject to change due to technical modification or improvement without any prior...

Страница 3: ...type 9 52 Expansion device Capillary tube Defrosting system Microcomputor controlled reverse system Fan System Indoor air circulation Hi Cooling m3 h 1200 1200 Indoor fan type Cross flow Cooling rpm 1...

Страница 4: ...oller 6 2 5 3 7 1 1 1 Air Conditioner Service Manual Operation Details Remote Control The remote controller is not presetted as Cooling Only Air Conditioner or Heat Pump by manufacturer Each time afte...

Страница 5: ...e Initial RT Initial ST Cooling RT 26 23 Dehumifying 26 RT 20 18 Heating RT 20 23 Cooling only Mode Initial RT Initial ST Cooling RT 26 23 Dehumifying 26 RT 20 18 Ventilating RT 20 Under automatic mod...

Страница 6: ...ature changes lead to changes in airflow speed the switch can only be made orderly and every grade of air flow speed runs 1 minute at least 4 Vane motor control run as set state 5 4 way valve control...

Страница 7: ...g temperature droping when compressor operating not including the compressor s starting course and the machine runs into defrosting according to any one condiciton as below Running into defrosting und...

Страница 8: ...e quitting conditions for option 3 When OPT 20 C or defrosting for more than 10 min then quit from defrosting 3 Defrosting process shown in Figure 4 Figure 4 Defrosting process 7 Auxiliary Electric he...

Страница 9: ...buzzer rings once and to release the machine runs into cooling mode if to holding on the buzzer rings twince then the machine runs into heating mode while when the machine is on to press the emergency...

Страница 10: ...or and the compressor open indoor fan motor restores the original state 4 Anti cold wind control in heating a When runing into the heating mode once the compressor fails to comply with the start up co...

Страница 11: ...sor failures appear the compressor stops and indoor and outdoor fan motors shut off Remote controller deesn t response to any signal except for shutdown During failure the machine can run in fan mode...

Страница 12: ...Air Conditioner Service Manual 12 WIRING DIAGRAM MODEL BSZ 30H INDOOR UNIT OUTDOOR UNIT...

Страница 13: ...Air Conditioner Service Manual 13 EXPLOSION VIEW MODEL BSZ 30H INDOOR UNIT 8 13 11 12 10 9 6 7 5 4 3 1 2 17 14 15 16 18 20 1 26 25 23 21 22 24 27...

Страница 14: ...Air Conditioner Service Manual 14 EXPLOSION VIEW MODEL BSZ 30H OUTDOOR UNIT 10 11 8 9 6 7 5 4 20 14 12 13 15 16 17 18 19 3 2 21 22 24 23 25 26 1 27 29 28...

Страница 15: ...B Cover 1 14 1070850180 Up Vane 1 15 1070850181 Down Vane 1 16 1070110012 Drainage Hose 1 17 1070850140 Cable Clamp 1 18 1170020023 Vane Motor 2 19 1170200051 Terminal 1 20 1073030201 Sensor Holder 1...

Страница 16: ...1081990039 Right Plate 1 16 1120120011 Two way Valve 1 17 1081990041 Valve Supporter 1 18 1120130013 Three way Valve 1 19 1073551103 Electrical Box Cover 1 20 1074060118 Cable Clamp 1 21 1170200054 T...