BV225 Amplifier
Installation Instructions
2
BV225 Installation Manual issue 3
Over temperature protection is provided using sensors attached
to the output stage heat sink. Should the temperature exceed 90
Degrees Celsius the input signal to the relevant amplifier will be
attenuated to a safe level and the “Overload” LED will be
illuminated.
If the system is under surveillance it will cause the surveillance
detector to indicate a fault condition due to the gain reduction.
1.2 BV225 A
MPLIFIER
S
PECIFICATIONS
Parameter
Value (Per Amplifier)
Rated output power less than 0.2% THD
225W @ 44.5
Ω
Output regulation 225W @ 44.5
Ω
Better than 1.5dB
Output Voltages obtainable
50V & 100V
Frequency response 225W @ 44.5
Ω
(-3dB)
35Hz - 20kHz
Input sensitivity and impedance
500mV @ 40K
Ω
Input common mode rejection ratio (50Hz - 20kHz)
Better then 40dB, typically 60dB
Output noise reference to rated output
Better than 85dB
Cross talk between amplifiers @ 1kHz
Better than 70dB
Supply Voltage
22V - 35V DC
Supply Current: Sleep mode @ 26V (Battery supply)
50mA
Supply Current: Quiescent @ 30V (Mains supply)
160mA
Supply Current: Rated output power 225W @ 44.5
Ω
10A
Supply DC Fuse (Automotive Style Blade)
15A
Output Stage Protection: Thermal
Output stage above 90°C
Output Stage Protection: Load
Excessive Output Stage Current
Output Stage Protection: Action
Reduces input to a safe level
Front Panel Indicators
Power (Green)
DC Supply Connected
Overload (Yellow)
Protection circuit operating
100% (Yellow)
100V Output Voltage
10% (Green)
10V Output Voltage
Terminations
Loudspeaker 100V Line Output
2 off 3 way cage clamp
Balanced Line Inputs
2 off RJ45 connectors
DC Supply Input
2 pin crimp connectors