Section 4
Setup and Operation
4-1
Setup and Operation
MN715P
Overview
The operator interface panel is shown in Figure 4-1.
Figure 4-1 Operator Interface
J4 Control Terminal Strip
J5 Power Terminal Strip
Power
GND
Motor
GND
L1 L2 L3
T1 T2 T3
B-
R2 R1
1
P1 P2
P3 P4P5
P6
S1
DIP Switch
(All OFF =
factory settings)
POWER
FAULT
FWD
REV
STOP
0
10
20
30
40 50 60
70
80
90
100
% Speed
Potentiometers
P1 Ć P6
POWER
LED is on when AC input power is applied to the control.
FAULT
LED is on when a fault condition is present in the control.
FWD
Press FWD to initiate forward rotation of the motor, in local command mode.
LED is on when control is in forward run mode.
REV
Press REV to initiate reverse rotation of the motor, in local command mode.
LED is on when control is in reverse run mode.
STOP
Press STOP to initiate a stop sequence, in local or remote modes. Depending
on the setting of potentiometer P2, the motor will either ramp or coast to a
stop. The LED is on when the control is in stop mode.