1
Instruction Manual For D
−
Series Replacement Rectifier Package
SAFETY NOTICE
: WARNING statements
describe conditions that may lead to personnel
injury including potentially fatal injuries if the machine is improperly used and
warnings are not followed.
Caution statements describe conditions that may lead to equipment
damage.
WARNING:
Be sure to read and follow all Instruction, Warning and Caution
statements in the appropriate motor manual. Failure to do so may
result in serious or fatal injury.
WARNING:
Only qualified personnel should attempt the installation, operation
and maintenance of this equipment. Proper guards and other suitable
safety devices or procedures as may be desirable or as may be
specified in safety codes, are neither provided by Baldor nor are the
responsibility of Baldor. Safety devices are the owners responsibility.
WARNING:
Disconnect all electrical power from the motor and accessory
devices and TAG Power Source before performing this procedure.
Electrical shock can cause serious or fatal injury.
Receiving & Inspection
When you receive your control, there are several things you should do
immediately.
1. Observe the condition of the shipping container and report any damage
immediately to the commercial carrier that delivered your control.
2. Remove the control from the shipping container and remove all packing
materials from the control. The container and packing materials may be
retained for future shipment.
3. Verify that the part number of the control you received is the same as the part
number listed on your purchase order.
4. Inspect the control for external physical damage that may have been
sustained during shipment and report any damage immediately to the
commercial carrier that delivered your control.
Description
This rectifier package is made for the D
−
Series Motor Brake. It provides either full
wave rectification (low voltage) or one
−
half wave rectification (high voltage) of AC
voltage input. The standard D
−
Series VAC Motor Brake has a rectifier located on the
brake coil internal to the brake. If the brake initially had the incorrect coil or was wired
incorrectly, this internal rectifier could be blown. The resistance of the brake coil must
be measured between brake leads B4 and B5 to ensure that the brake coil is the
correct coil and still intact. The proper resistance values are shown in Table 1. Only
if the coil resistance is verified to be correct should this replacement rectifier package
be used. This package is capable of operating at any of the standard D
−
Series Brake
nameplate voltages 104 through 575 VAC, 50 or 60 Hz.
Mounting
The Replacement Rectifier Package may be placed inside the motor conduit box.
The Replacement Rectifier Package dimensions are shown in Figure 1.
Figure 1
0.625
2.140
1.140
Wire leads are 6" long