Baldor Electric Company
World Headquarters
P.O. Box 2400 Ft. Smith, AR 72902-2400
(479) 646-4711 Fax (479) 648-5792
www.baldor.com
Baldor Electric Company
8/08
All rights reserved. Printed in USA
MN412
2
Table 1
Coil Voltage
Low/High
3 & 6 lb-ft
Resistance (ohms)
10 through 50 lb-ft
Resistance (ohms)
115/230VAC
562
387
230/460VAC
2078
1550
287/575VAC
2987
2245
104/208VAC
384
290
190/380VAC
1341
923
250/500VAC
2336
1793
Wiring
Caution:
Do not use connection diagram on the brake label! Connect brake
as described here only. Failure to connect as shown could result in
damage to the replacement rectifier circuit.
Refer to Figure 2 for the correct connection information.
Failure to follow Figure 2 can damage the Coil/Rectifier Package.
Figure 2
Rectifier Package
LOW VOLTAGE AC
WHITE
POWER LINE A
(WITH MOTOR)
BLACK
POWER LINE B
(WITH MOTOR)
BLUE
B4 BRAKE
RED
B5 BRAKE
B1 BRAKE
CAP ALONE
B2 BRAKE
CAP ALONE
B3 BRAKE
CAP ALONE
HIGH VOLTAGE AC
WHITE
B4 BRAKE
BLACK
BLUE
CAP ALONE
RED
B5 BRAKE
B1 BRAKE
CAP ALONE
B2 BRAKE
CAP ALONE
B3 BRAKE
CAP ALONE
OPTIONAL HIGH VOLTAGE AC CONNECTION FOR
NEMA 2 WYE Wound Motor
T1 MOTOR
L1 POWER
T2 MOTOR
L2 POWER
T3 MOTOR
L3 POWER
T4 MOTOR
WHITE KIT
T7 MOTOR
T5 MOTOR
BLACK KIT
T8 MOTOR
T6 MOTOR
T9 MOTOR
B1 BRAKE
B2 BRAKE
B3 BRAKE
BLUE KIT
B4 BRAKE
RED KIT
B5 BRAKE
POWER LINE A
(WITH MOTOR)
POWER LINE B
(WITH MOTOR)