Installation
Increasing Power Spring Tension:
1. Pull the hose out fully and engage the
stop pawl.
2. Be sure the system pressure has been
relieved,
follow the pressure relief pro
cedures below.
3. Remove the bumper stop and dispensing
valve.
4. Pull the hose back through the roller
outlet and wrap one loop of hose around
the spool.
5. Pull the hose back through the roller
outlet assembly and check the spring ten
sion; the hose must pull out fully and
retract fully. Continue to wrap more
loops, one at a time until the power
spring has the desired tension.
Adjusting the Outlet Arm Position:
Tank/Mobile Mounting Position:
1. Pull the hose out fully and engage the
stop pawl. Place C-clamp on spool to
prevent possible bodily injury
(see figure 8).
2. Remove screws (11) from the roller outlet
assembly and remove screws (11 & 12)
which hold the top tie bracket and outlet
arm assembly to the uprights. Reverse
the position of the roller outlet assembly
as shown in figure 10 and replace screws
(see figure 11).
Do Not
put so many loops onto the reel that the
power spring winds tightly before the hose is fully
extended. A power spring that has been wound
too tight stops rotating before the hose is fully
extended. This condition will wear the hose and
power spring prematurely. To decrease tensioin,
remove one to two loops of hose from the reel.
CAUTION
!
Before removal of the roller outlet assembly and
the top tie bracket, the power spring tension
should be removed and the uprights should be
secured against accidental separation.
CAUTION
!
Pressure Relief Procedure:
Follow this procedure before maintaining and/
or repairing your Premium Hose Reel and/or any
part of the system.
1) Disconnect the air to the pump.
2) Point dispensing valve away from yourself and
others
3) Open dispensing valve until pressure is
relieved.
WARNING
!
8