Product Description

The  5:1  ratio  Panther

®

  pump  is  suitable  for  simultaneous  fluid  distribution  of  up  to  four  dispense 

points, or for pumping to distances of up to 750 feet.  The 3:1 ratio Panther

®

 can service as many 

as five dispense points at up to 500 feet.     

The Panther's air motor features a precision air reversing valve mechanism with dual valve ports 

for  improved  high  speed  breathing.    It  also  contains  a  positive  trip  detent  spool  mechanism  that 

eliminates  stalling  (blowing  air)  when  the  pump  is  caught  between  strokes.    It  has  a  simple  yet 

durable  construction  with  all  internal  parts  lubricated  at  the  factory  using  a  life-tested  synthetic 

grease (Balcrank

®

 P/N 826733).  This grease coats all internal parts and repels air line moisture 

to inhibit corrosion.
The Panther

®

 pumping assembly features a nitrided steel pump rod and foot valve for superior wear 

and corrosion resistance.  The pump's exterior is constructed from aircraft grade extruded aluminum 

for an outstanding strength-to weight ratio.  The pump also has high quality Buna-N seals and is 

packaged in a pump that has proven reliable yet easy to service and maintain.

Technical Data

Pressure Ratio 

3:1 

5:1

Air Motor, Effective Dia. 

2.44" 

2.44"

Stroke 

3.0" 

3.0"

Air Motor Displacement 

28.86 in

3

 

28.86 in

3

Cycles per Gallon 

28 

44

Maximum Flow Rate 

8.5 GPM 

7.0 GPM

Operating Air Pressure Range 

10-125 psi 

10-125 psi 

 

(.69-8.6 Bar) 

(.69-8.6 Bar)

Recommend Operating Range

 

40-125 psi 

40-125 psi

 

(2.8-8.6 Bar) 

(2.8-8.6 Bar)

Air Consumption, @ 100 psi Air

1

 

38 SCFM 

45.6 SCFM 

 

Fluid Suction Lift 

20 In. Hg. 

20 In. Hg.

Common Specifications:

Port Sizes:  Fluid Inlet 1" NPTF/1-1/2" NPTM,  Fluid outlet 1/2" NPT,  Air inlet 1/4" NPT

Wetted Parts:  Nickel Plated Steel, Nitrided Steel, Brass, Aluminum, Buna-N

TM

Compatible Fluids:  Petroleum and synthetic motor oils, gear oil, ATF, hydraulic oil

Operation ........................................................ 5
Pump Repair/Servicing ................................... 5
Troubleshooting Guide ................................... 7
Parts List.................................................... 8-13
Parts Diagram............................................ 8-13
Warranty Statement ...................................... 14

Model 1130-010 

       Model 1130-011

1.  Air consumption varies with pump speed.

Содержание PANTHER 1130-010

Страница 1: ...and this manual before installing operating or servicing this equipment OPERATION INSTALLATION MAINTENANCE AND REPAIR GUIDE SERVICE BULLETIN SB1037 Rev J 1 11 PANTHER SERIES PUMPS 5 1 RATIO MODEL 1130 011 3 1 RATIO MODEL 1130 010 ...

Страница 2: ...ystem 1 Disconnect the air to the pump 2 Point dispensing valve away from yourself and others 3 Open dispensing valve until pressure is relieved WARNING WARNING THIS PUMP CONTAINS ALUMINUM AND ZINC PARTS DO NOT use 1 1 1 Trichloroethane methylene chloride or other halogenated hydrocarbon solvents or fluids containing such solvents in this pump Use of these solvents fluids may result in a violent c...

Страница 3: ...and foot valve for superior wear and corrosion resistance The pump s exterior is constructed from aircraft grade extruded aluminum for an outstanding strength to weight ratio The pump also has high quality Buna N seals and is packaged in a pump that has proven reliable yet easy to service and maintain Technical Data Pressure Ratio 3 1 5 1 Air Motor Effective Dia 2 44 2 44 Stroke 3 0 3 0 Air Motor ...

Страница 4: ...pump fluid entry port Attach the air nipple to the air inlet port of the Panther pump During assembly of the air supply line be sure to blow out all foreign materials before making connection to the pump Balcrank recommends that an air line lubricator be used with turbine oil viscosity 150 170 SSU 100 0 F and set at a maximum oil feed rate of 2 drops per minute of pump operation The pump air motor...

Страница 5: ...Pump Operation WARNING Before beginning pump repair all internal pressure must be relieved To reduce risk of personal injury follow the Pressure Relief Procedure shown on page 2 and page 6 Pump Disassembly Reassembly Using a soft jaw vise or a suitable fixture clamp the pump vertically on the upper body 4 If a vise is unavailable simply place the pump cap down on a work bench Refer to illustration...

Страница 6: ...ief Procedure Pressure Relief Procedure To reduce the risk of serious bodily injury including fluid injection or splashing into the eyes and or onto the skin follow the procedure below before maintaining or repairing the pump the solenoid or any part of the system 1 Disconnect the air supply from the pump 2 Open the dispensing valve into an approved waste container to relieve pres sure on the syst...

Страница 7: ...pump at lower pressure run at lower cycles per minute clean muffler 38 Pump runs continuously Empty fluid supply Refill reprime or flush Blockage in pump tube or foot valve 16 Remove pump tube clear blockage Lower ball 14 is stuck in foot valve 16 Replace ball and reseat foot valve Lower seal 21 is worn or damaged Replace Fluid output on one stroke only or Upper ball 19 is stuck in fluid piston 20...

Страница 8: ... 1 0 0 5 12 826676 Seal Adapter 1 0 1 13 829457 Cylinder Pump 1 0 0 14 808691 Ball 1 0 1 15 830306 Seal Footvalve 1 0 1 16 829458 Footvalve prior to 4 2003 1 0 0 826060 Footvalve after 4 2003 1 0 0 17 829769 Pin Stop 1 0 1 18 829466 Rod Displacement 1 0 0 19 806962 Ball 1 0 1 20 829465 Fluid Piston 1 0 0 21 816853 O Ring Buna N 1 0 1 900014 900009 Note Replacement parts can be sold as individual p...

Страница 9: ...9 Exploded View Panther 3 1 Ratio Pump Model 1130 010 See Page 12 ...

Страница 10: ...489 Grounding Lug 90042Q05 1 0 0 5 12 800951 Seal Adapter 1 0 1 13 829459 Cylinder Pump 1 0 0 14 806962 Ball 1 0 1 15 829893 Seal Footvalve 1 0 1 16 829460 Footvalve 1 0 0 17 829662 Pin Stop 1 0 1 18 829454 Rod Displacement 1 0 0 19 827761 Ball 1 0 1 20 829456 Fluid Piston 1 0 0 21 800360 O Ring Buna N 1 0 1 900014 900010 Note Replacement parts can be sold as individual parts items listed with par...

Страница 11: ...11 Exploded View Panther 5 1 Ratio Pump Model 1130 011 See Page 12 ...

Страница 12: ...12 Air Motor Panther Series Pumps Models 1130 010 and 1130 011 23 ...

Страница 13: ...O Ring 4 4 36 829461 Retnr Detent 2 2 37 829661 Spring Detent 2 2 38 805810 Ball Detent 2 2 39 831553 O Ring 1 1 40 830793 Piston Air 1 0 41 829659 Felt Muffler 90036Q20 1 0 20 42 829999 Spool Detent 1 1 43 830791 Valve Intake 2 2 44 829445 Screen Muff 90035Q12 1 0 20 45 830723 Coupler Rod 1 0 900014 Note Replacement parts can be sold as individual parts items listed with part number as a set in P...

Страница 14: ...air kit for 1130 010 1130 011 Panther pumps without Delrin inserts 900015 Air motor repair kit for Panther grease pumps 1150 006 1150 007 1150 008 Does not include piston 900016 Repair kit for lower assembly for Panther grease pumps 1150 006 1150 007 1150 008 900019 Air motor repair kit for 1130 015 1130 016 Panther pumps 900020 Fluid seals kit for Panther 1130 015 pumps 900021 Fluid seals kit for...

Страница 15: ...15 Notes ...

Страница 16: ...Balcrank Corporation Weaverville NC 28787 800 747 5300 Fax 800 763 0840 www balcrank com Service Bulletin SB 1037 Rev J 1 11 For Warranty Information Visit www balcrank com ...

Отзывы: