System Revision History

System PN

EPN

Date

Requested By

Changes Made

56016

1954 09.20.2006 Balboa

New system

56016

2528 09.25.2007 Balboa

Update to 48A service YCAH

56016

2528 10.05.2007 Balboa

Software update to v41, A5 ON

56016

2528 10.18.2007 Balboa

Software revert to v39

56016-01

2765 04.08.2008 Balboa

Software update to v43

Содержание VS520DZ

Страница 1: ...f 04 08 2008 Template used 40600_P pdf 01 07 2008 Balboa Instruments System PN 56016 01 System Model VSP VS520DZ YCAH Software Version 43 EPN 2765 Base PCBA PN 55152 01 PCB VS500Z PN 22972 Rev D or E Base Panels VL801D Serial Deluxe PN 54108 VL802D PN 54528 ...

Страница 2: ...By Changes Made 56016 1954 09 20 2006 Balboa New system 56016 2528 09 25 2007 Balboa Update to 48A serviceYCAH 56016 2528 10 05 2007 Balboa Software update to v41 A5 ON 56016 2528 10 18 2007 Balboa Software revert to v39 56016 01 2765 04 08 2008 Balboa Software update to v43 ...

Страница 3: ... NEUTRAL GROUND System Outputs BALBOA INSTRUMENTS INC VS500Z P N 22972 REV D MADE IN U S A COPYRIGHT 2005 J7 J8 J44 J60 J22 U4 FUSE K8 K5 J1A J10 J13 J2A EXT RLY AUX F SEN A SEN B VAC J1 J2 W2 W3 J12 1 2 3 2 SPD EXT RLY J18 Basic System Features and Functions Setup 1 As Manufactured s 6 0UMP 3PEED s 6 0UMP 3PEED s 6 LOWER s 6 ZONE s 6 3PA IGHT s 6 6 Stereo s 6 K7 EATER Optional Devices s 6 IRC 0UM...

Страница 4: ... that is a VS511SZ at version 38 s Displayed next is indicating the system is configured for a heater between 3 and 6 kW or indicating the system is configured for a heater effectively between 1 and 3 kW should appear for all VS models running at 240VAC should appear for all VS models running at 120VAC as well as all GS models A heater which is rated at 4 kW at 240VAC will function as a 1 kW heate...

Страница 5: ...2 Spd P1 PCBA Rev D E only Black jumper required Do not remove Wiring Configuration and DIP Settings Setup 1 As Manufactured s 6 0UMP 3PEED s 6 0UMP 3PEED s 6 LOWER s 6 ZONE s 6 3PA IGHT s 6 6 Stereo s 6 K7 EATER s 6 6 AIN 0ANEL s 6 IRC 0UMP OPTIONAL A1 Test Mode OFF A2 See Table 1 A3 N A A7 J17 26 Disabled A10 See Table 1 A9 Non Circ Mode A5 2 speed P1 Panel Button Assignments 1 Time 2 Mode Prog ...

Страница 6: ...g DIP switches incorrectly may cause abnormal system behavior and or damage to system components sRefer to Switchbank illustration on Wiring Configuration page for correct settings for this system sContact Balboa if you require additional configuration pages added to this tech sheet Panel Button Positions Aux Panel Information Panel Button Assignments 1 Time 2 Mode Prog 3 Temp Up 4 Temp Down 5 Lig...

Страница 7: ... J29 See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC The voltage to the ozone connector can be changed in the field if required W2 just needs to be set for the required voltage WARNING Changing the voltage of the ozone connector also effects the voltage su...

Страница 8: ...N 54108 with Overlay PN 10763 s Connects to Main Board terminal J1 only S ETUP 1 Blower Time Warm Mode Prog Cool Jets 1 Light Jets 2 VL802D PN 54528 with Overlay PN 11789 s Connects to Main Board terminal J1 only Panels with back lighting bulbs installed should never be plugged into J2 Use J1 only If the backlight bulbs are removed then both J1 and J2 may be used ...