background image

Your system has a 24-hour circ pump.  The circ pump 
and the ozone generator run continuously.

Warm/Cool (80°F - 104°F / 26°C - 40°C)

The start-up temperature is set at 100F°/37°C.  The last 
measured temperature is constantly displayed on the LCD.

Note that the last measured spa temperature displayed is 
current only when the circ pump has been running for at 
least 2 minutes.

To display the set temperature, press the “Warm” or “Cool”
pad once.

To change the set temperature, press the pad a second time before 
the LCD stops flashing.  Each press of the “Warm” or “Cool” pad 
will continue to either raise or lower the set temperature.

After three seconds, the LCD will stop flashing and display the 
current spa temperature.

Jets 1

Touch the “Jets 1” button once to turn pump 1 on or off, and 
to shift between low and high speeds (if equipped).  If left 
running, the low speed of the pump will automatically turn off 
after 4 hours, and the high speed will automatically turn off after 
15 minutes.

Jets 2

 (If equipped)

Touch the “Jets 2” button once to turn pump 2 on or off.  If left 
running, pump 2 will automatically turn off after 15 minutes.

Blower

(If equipped)

This button is used to turn the blower on and off.  If left on, the 
blower automatically turns off after 15 minutes.

Light

Press the “Light” button to turn the light on and off.  If left on, 
the light automatically turns off after 4 hours.

(over)

VS510S/GS510S Control Reference Card

Circ Operation

Initial Start-up

When your spa is first actuated, it will go into Priming mode, indicated by “

.”

Please see the M-7 Installation Instruction Manual 

for complete instructions on Power-up and Pump Priming

.  

The Priming mode will last for less than 5 minutes (press “Warm” or 

“Cool” to skip Priming Mode) and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode.

Mode

Mode is changed by pressing the “Warm” or “Cool” button, then 
pressing the “Mode” button.

Standard Mode

 is programmed to maintain the desired 

temperature.  Note that the last measured spa temperature 
displayed is current only when the circ pump has been running 
for at least 2 minutes.  “

” will be displayed momentarily 

when you switch into Standard Mode.

Economy Mode

 heats the spa to the set temperature only 

during filter cycles.  “

” will display solid when temperature 

is not current, and will alternate with temperature when 
temperature is current.

Sleep Mode 

heats the spa to within 20°F/10°C of the set 

temperature only during filter cycles.  “

” will display 

solid when temperature is not current, and will alternate with 
temperature when temperature is current.

Preset Filter Cycles

The first filter cycle begins 6 minutes after the spa is energized.  
The second filter cycle begins 12 hours later.  Filter duration is 
programmable for 2, 4, 6, 8 hours or for continuous filtration 
(indicated by “

”).  The default filter time is 2 hours.

To program, press “Warm” or “Cool”, then “Jets 1”.  
Press “Warm” or “Cool” to adjust.  Press “Jets 1” to 
exit programming.

At the beginning of each filter cycle the blower purges for 
30 seconds; the pumps purge for 5 minutes.  The only effect 
filter duration has is: 1) During the filter, the circ pump never 
turns off, and 2) In Economy and Sleep Modes, heating only 
occurs during the filter cycle.

Freeze Protection

If the temperature sensors detect a drop to below 44°F/6.7°C 
within the heater, the pumps and blower will automatically 
activate to provide freeze protection.  The equipment stays on 
until 4 minutes after the sensors detect that the spa temperature 
has risen to 45°F/7.2°C or higher.  In colder climates, an 
optional additional freeze sensor may be added to protect against 
freeze conditions that may not be sensed by the standard sensors.  
Aux freeze sensor protection acts similarly except with the 
temperature thresholds determined by the switch and without a 
4-minute delay in turnoff.  See your dealer for details.

Jets

Light

Warm

Cool

Mode

Jets

Blower

Light

Heat

Jets

Light

Warm

Cool

Mode

Jets

Blower

Light

Heat

*Actual buttons and locations may vary

VS Systems display in °F
GS Systems display in °C