background image

 

 

 

ELECTRICAL  SAFETY  INSTRUCTIONS 

 
1.  Read & follow all safety instructions.

 

 

2.  A green colored terminal or a terminal marked G, GR, Ground, Grounding, or the international symbol is located inside the supply 

terminal  box  or  compartment.  To  reduce  the  risk  of  electric  shock,  this  terminal  must  be  connected  to  the  grounding  means 

provided  in  the  electric  supply  panel  with  a  continuous  copper  equivalent  in  size  to  the  circuit  conductors  supplying  this 

equipment.

 

 

3.  The equipment must be provided with a ground fault circuit interrupter located in the disconnect switch, as installed by a licensed 

electrician.  

4.  The electrical service panel should be equipped with a 20-amp switch.   
5.  The electrical supply for the spa must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors, 

to comply with section 422-30 of the National Electrical Code, ANSI/NFPA 70-2002.  The disconnecting means must be readily 

accessible to the spa occupant, but must not be within 5 feet (1.52 m) of the spa. 

6.  All field-installed metal components such as rails, ladders, drains or other similar hardware within 3 meters of the spa shall be 

bonded to the equipment grounding bus with copper wire conductors not smaller than No. 6 AWG.

 

 

7.  For units intended for use other than single family dwellings, a clearly labeled emergency switch shall be provided as part of the 

installation. The switch shall be readily accessible to the occupants and shall be installed at least 5 feet (1.52 m) away, adjacent 

to, and within sight of, the unit

 

 

8.  WARNING:  Improper electrical connections or conductor sizing may cause the equipment module to operate improperly, create 

the potential for an electrical hazard, and may void the warranty.  

9.  CAUTION:  Use only approved pressure-type wire splicing lugs or connectors suitable for the size and type of wiring used.   

 

If your hot tub is equipped with audio components, the following instructions also apply: 

1.  CAUTION - Risk of Electric Shock. Do not leave component access panel open.

 

 

2.  CAUTION - Risk of Electric Shock. Replace components only with identical components.

 

 

3.  CAUTION - Do not operate the audio components while inside the spa.

 

 

4.  WARNING  -  Prevent  Electrocution.  Do  not  connect  any  auxiliary  components  (for  example  cable,  additional  speakers, 

headphones, additional audio/video components, etc.) to the system.

 

 

5.  These units are not provided with an outdoor antennae; when provided, it should be installed in accordance with Article 810 of the 

National Electrical Code, ANSI/NFPA 70.

 

 

6.  Do not service this product yourself as opening or removing covers may expose you to dangerous voltage or other risk of injury. 

Refer all servicing to qualified service personnel.

 

 

7.  If  the  power supply  connections  or  power  supply  cord(s)  are  damaged;  if  water is  entering  the  audio  equipment compartment 

area; if the protective shields or barriers are showing signs of deterioration; or if there are signs of other potential damage to the 

unit, turn off the unit at the disconnect switch and refer servicing to qualified service personnel.

 

 

8.  This unit should be subjected to periodic routine maintenance (for example, once every 3 months) to make sure that the unit is 

operating properly.

 

 

9.  Replace damaged cord immediately.

 

 

10.  Do not bury electrical cables or cords.

 

 

 

Содержание Tranquility Series

Страница 1: ...Owner s Manual 2012 Important Information Enclosed Please read before setting up or using your spa Rev 1 1 12 MODELS ER15 ES15 ER23 ES25 EG4 and EG5 ...

Страница 2: ...WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times 8 A wire connector is provided on this unit to connect a minimum No 8 AWG 8 4mm2 solid copper conductor between this unit and any metal equipment metal enclosures of electrical equipment metal water pipe or conduit within 5 feet 1 52 m of the unit 9 Excessive water temper...

Страница 3: ... WARNING Improper electrical connections or conductor sizing may cause the equipment module to operate improperly create the potential for an electrical hazard and may void the warranty 9 CAUTION Use only approved pressure type wire splicing lugs or connectors suitable for the size and type of wiring used If your hot tub is equipped with audio components the following instructions also apply 1 CAU...

Страница 4: ...ced on a solid flat and level surface that does not move or shake 7 You should consult with a builder or engineer to determine if your floor will support the spa weight Remember you must allow for the spa water and people in your total weight calculations 8 Be sure your spa is secure from access by young children We offer a locking spa cover but we also suggest keeping the spa room locked and off ...

Страница 5: ... Electrical Code N E C and local code requirements The connection must include the conductors necessary for operation and bonding as required by N E C 1 Remove the spa from its shipping container and retain all safety operation and warranty information 2 Position the spa on a flat level surface such as concrete or a wood deck which provides adequate drainage 3 Position the spa at least 5 feet from...

Страница 6: ...ion at the equipment module You should re check the tightness of the fittings and placement of the O rings Check that the filter is positioned in the skim filter system 6 Activate the power to your spa Refer to the Control Panel Instruction section of this manual Spas running on 110v will heat at an average of 1 2 per hour Not to scale May vary by model 1 1 2 6 3 8 5 4 7 2 1 2 3 4 5 6 7 8 GATE VAL...

Страница 7: ...you must properly test and maintain your spa water for health and appearance reasons Chemical imbalance can cause skin irritations and dirty water is both unsightly and undesirable to soak in With little effort you can have clean water for your constant enjoyment This is attained through the use of spa chemicals a superb filter system and the optional ozonator Consult your dealer to set up a prope...

Страница 8: ...de surface Bug Tar Remover or OOPS Do not use an abrasive brush or cleaning agent as it will scratch the finish DO NOT USE any of the following items to clean your tub Acetone Goof Off or any cleaners that contain esters ethers ketones aromatic or chlorinated hydrocarbons Isopropanal concentrations greater than 25 If you have stubborn dirt or scum marks at the water line use a spa cleaner and a sc...

Страница 9: ... sure that the thermostat is set to keep the water warm If you intend on closing down your spa for the winter you should follow the winterizing procedures listed below 1 Drain the spa as explained in the Draining Your Spa section 2 Be sure that all water is removed from the spa 3 Shut off all electrical power at the breaker box 4 Disconnect the unions from the equipment module to allow the water i...

Страница 10: ...ower input terminals figure 2 5 Locate the 14 AWG jumper wire between White AC terminals and Red AC terminals and remove discard figure 2 6 Locate Switchbank A near the bottom center of the circuit board and adjust DIP switch 10 to the OFF position High Amperage mode see figure 4 7 Connect 240VAC input wiring to terminal block Refer to figure 3 for proper conductor connections 8 Attach the front c...

Страница 11: ...Mode press Jets button repeatedly and be sure the pump is free of air Priming Mode lasts less than 5 minutes Press the Warm or Cool button to exit After Priming Mode the spa will run in Standard Mode see Mode section Pump 1 low speed is responsible for heating and filtration and will be referred to simply as the pump In multi button sequences if the buttons are pressed too quickly in sequence they...

Страница 12: ...e current water temperature will be displayed DO NOT ENTER THE WATER Remove the spa cover and allow water to cool Once the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer DO NOT ENTER THE WATER Remove the spa cover and allow water to cool At 107 F 41 7 C the spa should automatically reset If spa does not reset shut of the power...

Страница 13: ...el hot water coming from the jets Make sure all valves are open to allow full water flow through the system Limited water flow will NOT build enough pressure to allow the heater to come on Clean the filter to assure maximum water flow Pulsating Or Minimal Water Flow In High Speed Mode Make sure water level of the spa is at least 2 above the skim filter Be sure jets are turned open see Spa Operatio...

Страница 14: ..._________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________...

Страница 15: ...cated or 4 commercialorpublicuseofthe spa Warranty coverage shall not extend for any reason beyond the stated periods The warranties as set forth and limited herein are the sole and exclusive warranties made by Emerald and Emerald hereby expressly disclaims any other warranties express or implied EMERALD HEREBY EXPRESSLY DISCLAIMS THE IMPLIED WAR RANTIES OF NON INFRINGEMENT MERCHANTABILITY AND FIT...

Страница 16: ... OR TO OP TIONAL PARTS OR SYSTEMS WHICH ARE PURCHASED FOR INCLUSION ON OR IN THE SPA EMERALD SHALL HAVE NO RESPONSIBILITY TO AID IN THE ENFORCEMENT OF ANY WARRANTIES AGAINST MANUFACTURERS OF SUCH ITEMS PARTS SYSTEMS OR OPTIONS Optional Parts include without limitation ozone generator all audio systems and LED lighting Emerald shall not be liable for loss of use of the spa or other incidental or co...

Отзывы: