TROUBLESHOOTING
•
Equipment Module Will Not Operate
•
Make sure the spa control is plugged into the control system of the equipment module.
•
Check the main circuit breaker panel. If the GFCI or circuit breaker has tripped, reset the breaker.
•
Turn the circuit breaker, or switch, supplying power to the equipment module OFF then ON.
•
If breaker continues to trip, check with your electrician to be sure the proper amperage breaker was installed.
•
Pump Will Run But There Is No Water Flow
•
Make sure all valves are in the open position.
•
Make sure the filter is clean.
•
Make sure the suction intake covers are free of debris.
•
Make sure the water level of the spa is at least 2" above the skim filter.
•
Check to make sure all adjustable flow-type jets are turned open.
•
Pump Runs And There Is Water Flow But No Heat
•
Press the temperature set button to increase temperature. Do NOT expect to feel hot water coming from the jets.
•
Make sure all valves are open to allow full water flow through the system. Limited water flow will NOT build enough
pressure to allow the heater to come on.
•
Clean the filter to assure maximum water flow.
•
Pulsating Or Minimal Water Flow In High Speed Mode
•
Make sure water level of the spa is at least 2" above the skim filter.
•
Be sure jets are turned open (see "Spa Operation" section).
•
Make sure all valves are open.
•
Make sure the filter element is clean.
•
Make sure the suction intake covers are free of debris.
•
Pump Vibrates Excessively
•
Check for loose screws on equipment module face and bolts attaching equipment module to frame.
•
Make sure spa is not touching or rubbing against anything such as a deck rail, house, etc.
•
Air may be trapped in pump housing. Turn pump off. Slightly loosen the pump unions. With a towel covering the area
(water will splash) turn the pump on for 3-5 seconds to bleed air out of pump housing. Turn pump off and tighten the
unions. Repeat if necessary.
•
Make sure that the spa has been installed on a properly supported surface.