- 6 -
Priming the pump
As soon as the Priming Mode screen appears on the panel, select the
“
Jets 1
”
button once to start Pump 1 in
low-speed and then again to switch to high-speed. Also, select the other pumps, to turn them on. The pumps
should be running in high-speed to facilitate priming. If the pumps have not primed after 2 minutes, and water is
not flowing from the jets in the spa, do not allow the pumps to continue to run. Turn off the pumps and repeat the
process. Note: Turning the power off and back on again will initiate a new pump priming session. Sometimes
momentarily turning the pump off and on will help it to prime. Do not do this more than 5 times. If the pump(s) will
not prime, shut off the power to the spa and call for service.
Important: A pump should not be allowed to run without priming for more than 2 minutes. Under NO
circumstances should a pump be allowed to run without priming beyond the end of the 4-5 minute priming mode.
Doing so may cause damage to the pump and cause the system to energize the heater and go into an overheat
condition.
Exit Priming Mode
You can manually exit Priming Mode by navigating to the
“
Back
”
button on the Priming Mode Screen. Note
that if you do not manually exit the priming mode as described above, the priming mode will be automatically
terminated after 4-5 minutes. Be sure that the pump(s) have been primed by this time.
Once the system has exited Priming Mode, the top-side panel will display the Main Screen, but the display will
not show the temperature yet, as shown below. This is because the system requires approximately 1 minute of
water flowing through the heater to determine the water temperature and display it.
or
*M019 is a Message Code. See Page
.
(2)SPA Behaviour
Pump
On the Spa Screen, select a
“
Jets
”
button once to turn the pump on or off, and to shift between low- and
high-speeds if equipped. If left running, the pump will turn off after a time-out period. The pump 1 low-speed will
time out after 30 minutes. The high-speed will time-out after 15 minutes.
On non-circ systems, the low-speed of pump 1 runs when the blower or any other pump is on. If the spa is in
Ready Mode, Pump 1 low may also activate for at least 1 minute every 30 minutes to detect the spa temperature
(polling) and then to heat to the set temperature if needed. When the low-speed turns on automatically, it cannot
be deactivated from the panel, however the high speed may be started.
Air Pump
Press the air pump botton “
“ once to turn the device on or off.
Circulation Pump Modes
If the system is equipped with a circ pump, it will be configured to work in one of three different ways:
1, The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a time when
the water temperature reaches 3
°
F (1.5
°
C) above the set temperature (most likely to happen in very hot
climates).
2, The circ pump stays on continuously, regardless of water temperature.
3, A programmable circ pump will come on when the system is checking temperature (polling), during filter cycles,
during freeze conditions, or when another pump is on.
The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in
the field.
Other device options may be available, like Blower, Light, Mist, etc.