Warning :
please read the following instructions before operation, which is a safety guaranty to
SPA users.
1
、
The system must be installed by qualified technicians, switch for electricity leakage should be installed at the place
convenient to be controlled.
2
、
The bathtub must be installed to the floor for safety purpose, if not, we won’t take responsibility for the lost of the bad
grounding!
3
、
Taking load capacity of the wires into consideration when installed, otherwise, this will impact normal function or even
occur safety accidents!
4
、
To ensure sanitation of SPA, those who have skin or infectious disease should not use it.
5
、
All the jets, fountains cannot be shut down while keep water pumps working simultaneously, for this will damage the
SPA heavily.
6
、
The first time to use SPA, before filling in water, please check and shut all drain valves, and all the jets, water pumps
must be highly tightened(they might be loose during transportation).
7
、
The old, kids and those with heart disease and low/high blood pressure should use the SPA cautiously and under the
care of the healthy adults; Without doctor’s professional instruction, pregnant women cannot use the SPA.
8
、
Risk
:
Under the state of alcohol, poison and drugs, it will be dangerous to use the SPA.
9
、
Make sure that water slips out of jets regularly, or the relative components will be damaged.
10
、
Protect from getting hurt, please check the water temperature to make sure if it is ok to use when using the SPA.
11
、
SPA input water temperature should not be over 42 Celsius degrees so as not to get hurt; 30-40 Celsius degree is the
safety scope for human body. When you have been in the SPA for over 10-15 minutes, please try to lower the water
temperature.
12
、
Before using the SPA drugs, please take the physical property into consideration, for example, granular or root-like
drugs must be walled within filter bag.
13
、
After finishing strenuous exercise please do not use the SPA right away.
14
、
If feeling unwell when or after you used the SPA, please stop it right away and go to see the doctor.
15
、
Do not move or open the lid of filter.
16
、
Excessive Exposure to the sun for long will damage the SPA surface, when you are not going to use the SPA, please
cover it up against the sunshine.
17
、
If you use the SPA often, please wash the paper element filter for one time every week.
18
、
The heat preservation cover is formed of foam, prevent kids playing on it.
19
、
When filling in water, water should be 1cm over the probe screw when installed China control system, and water 1cm
over all the jets when installed Balboa system.
20
、
No water or water level doesn't reach the probe screw or over all the jets, do not operate the spa.
21
、
If the spa not to use, please keep the maintenance doors locked well or tighten the screw.
22
、
All the maintenance must be done after electricity has been cut off.
23
、
After the repair work and maintenance, check if all the functions run well.
24
、
In the very cold areas or seasons, please keep the SPA connected with electricity, filled with enough water in the SPA,
so as to protect SPA from being frozen to be broken, or you can drain water completely and cover to seal it.
25
、
All the preservation and maintenance must be done by qualified professionals . For more service, please contact the
suppliers or sales agents.
26
、
The product must be permanently connected to the fixed wiring.
27
、
Parts incorporating electrical components must be located or fixed so that they cannot fall into the bath.
28
、
The product should be supplied through a residual current device (RCD) having a rated residual operated
current not exceeding 30mA.
29
、
If your SPA is placed in direct sunlight , as possible as you can, please avoid to place it on the glass floor or near
the location of the glass wall , specular reflection effects can lead too high temperature on partial skirt which
will cause skirt deformation.
30. The bearing of the water pumps may get stuck after this SPA hasn’t been used for a long time, so the water
pumps may not working when pressing the water-pump buttons on control panel. If the water pump not
working because of water bearing get stuck, then you can notice that no water current through jets or no
suction- force in the skimmer. Please shut down the power ,open the hem doors, find out the water pumps,
rotate the blade inside water pumps, turn on the power again, activate the water pumps by pressing the water-
pump buttons several times.
31. Sometimes, the water pumps may work or rotate slowly at the beginning and back to normal after working 2-3
seconds. If the water pumps still rotate slowly after 2-3 seconds, please press the water-pump buttons on panel
to re-activate the pumps.
32. When you notice the hum of the water pumps while pumps not working (no water current through jets) and
overheating water pump surface, please shut down power immediately. It results from air kept inside of water
pumps or pipes be block. Please check the water pumps and pipes, fix the problem , and turn on the power
again.
33. During installation of the SPA, please keep the whole construction area clean and clear .No mud or metal be
left beneath the SPA tub body or near the water pumps. Keep sufficient space for dissipating heat of the
working water pumps.