Страница 1: ...EN SPAS Installation and Directions of Use ...

Страница 2: ...oting page37 IX Warranty process page38 FR SAV INFORMATION VIDEO CONTACT EN AFTER SALES SERVICE INFORMATION VIDEO CONTACT DE REPARATUR SERVICE UND ERSATZTEILE INFORMATIONEN VIDEO KONTAKT ES SERVICIO POST VENTA INFORMACIÓN VIDEO CONTACTO IT SERVIZIO ASSISTENZA INFORMAZIONI VIDEO CONTATTO PT SERVIÇO PÓS VENDA INFORMAÇÕES VIDEO CONTATO PL SERWIS TECHNICZNY INFORMACJE WIDEO KONTAKT NE AFTER SALES SERV...

Страница 3: ...ystem and water 1cm over all the jets when installed Balboa system 20 No water or water level doesn t reach the probe screw or over all the jets do not operate the spa 21 If the spa not to use please keep the maintenance doors locked well or tighten the screw 22 All the maintenance must be done after electricity has been cut off 23 After the repair work and maintenance check if all the functions r...

Страница 4: ...erred to as Temperature Buttons Some panels only have a single Temperature Button Press a Temperature Button once and the current Set Temperature will begin to flash on the LCD The Set Temperature and the actual water temperature are often different While the numbers are flashing press a Temperature Button again to change the Set Temperature Press and hold for faster adjustment After the new Set T...

Страница 5: ...tration pump has been running for a minute or two Mode may appear when Jets 1 is activated Complete Reference Download the complete User Interface and Programming Guide at http service balboa instruments com zz40940_download zip User Interface and Programming Reference Standard Menus System Model BP Series Systems are BP5XX BP6XX BP1XXX BP2XXX Software Version 7 0 and later Panel Model TP600 Serie...

Страница 6: ...u can manually exit the priming mode after the pump s have primed Regardless of whether the priming mode ends automatically or you manually exit the priming mode the system will automatically return to normal heating and filtering at the end of the priming mode During the priming mode the heater is disable to allow the priming process to be completed without the posibility if energizing the heater...

Страница 7: ...ow This is because the system requires approximately 1 minute of water flowing through the heater to determine the water temperature and display it or M019 is a Message Code See Page 2 SPA Behaviour Pump On the Spa Screen select a Jets button once to turn the pump on or off and to shift between low and high speeds if equipped If left running the pump will turn off after a time out period The pump ...

Страница 8: ...use the temperature to flash Pressing a temperature button again will adjust the set temperature in the direction indicated on the button When the LCD stops flashing the spa will heat to the new set temperature when required If the panel has a single temperature button pressing the button will cause the temperature to fl ash Pressing the button again will cause the temperature to change in one dir...

Страница 9: ...as polling REST Mode will only allow heating during programmed filter cycles Since polling does not occur the temperature display may not show a current temperature until the heater pump has been running for a minute or two Circulation Mode under Pumps for other circulation modes If the spa is configured for 24HR circulation the heater pump generally runs continuously Since the heater pump is alwa...

Страница 10: ...t temperature is reached or 1 hour has passed After 1 hour the System will revert to Rest Mode This mode can also be reset by entering the Mode Menu and changing the Mode 5 Show and Set Time of Day Be sure to set the time of day Seting the time of day is important for determining filtration times and other back ground features TIME will flash on the display if no time of day is set in the memory 2...

Страница 11: ...y set but since the spa started at noon the filter cycles will run as programmed Flip Invert Display Note Some panels may have a dedicated FLIP button which allows the user to flip the display with a single button press 6 Restricting and Operation The control can be restricted to prevent unwanted use or temperature adjustment Locking the panel prevents the contiroller from being used but all autom...

Страница 12: ...tton the ONLY button that will work in the Unlock Sequence is the UP button Hold Standby Hold Mode M037 Hold Mode is used to disable the pumps during service functions like cleaning or replacing the filter Hold Mode will last for 1 hour unless the mode is exited anually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this feature...

Страница 13: ... set using a start time and a duration Start time is indicated by A or P in the bottom right corner of the display Duration has no A or P indication Each seting can be adjusted in 1 hour increments The panel calcualates the end time and display it actomatically ...

Страница 14: ...y Pumps and or a Blower will purge water from their respective plumbing by running briefly at the beginning of each filter cycle If Filter Cycles 1 is set for 24 hours enabling Filter Cycle 2 will initiate a purge when Filter Cycles 2 is programmed to begin 9 Light Timer Programming Light Timer Option If LIFE TIMER does not appear in the Main Menu the Light Timer feature is not enabled by the manu...

Страница 15: ...n 12 hr and 24 hr display RE MIN DERS Reminders Turn the reminder messages like Clean Filter On or Off CLN UP Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When it is available set the length of time Pump 1 will run after each use 0 4 hours are available DOL PHIN AD DRES Dolphin II and Dolphin III Applies to RF Dolphin only ...

Страница 16: ...ls 10 Utilities and Information INFO System Information sub menu The System Information Menu displays various settings and identification of the particular system As each item in the menu is highlighted the detail for that item is displayed at the bottom of the screen SSID Software ID Displays the software ID number for the System MODL System Model Displays the Model Number of the System SETP Curr...

Страница 17: ...lities In addition to INFO The Utilities Menu contains the following GFCI GFCI Test Feature not available on CE rated systems GFCI Test is not always enabled so it may not appear This screen allows the GFCI to be tested manually from the panel and can be used to reset the automatic test feature If the GFCI Test Feature is reset the device will trip within 7 days A B A B Sensor Temperatures When th...

Страница 18: ... 17 Utilities ...

Страница 19: ...st be shut off until a service person can correct the problem Forcing the GFCI Trip Test The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu The GFCI should trip within several seconds and the spa should shut down If it does not shut down the power and manually verify that a GFCI breaker is installed and that the circuit and spa are wired correctly Veri...

Страница 20: ...on a regular basis Utilities Fault Log A Little History can tell a lot The Fault Log stores up to 24 events in memory and they can be reviewed under the Fault Log Menu Each event captures a Fault Message Code how many days have passed since the fault Time of the fault Set Temperature during the fault and Sensor A and B temperatures during the fault General Messages ...

Страница 21: ...ion has been detected or the Aux Freeze Switch has closed and all pumps and blower are activated All pumps and blower are ON for at least 4 minutes after the potential freeze condition has ended or when the aux freeze switch opens In some cases pumps may turn on and off and the heater may operate during Freeze Protection This is an operational message not an error indication Water is too Hot OHS M...

Страница 22: ...ated Checks below Heater is Dry M027 There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must press any button to reset and restart heater start up See Flow Related Checks below Heater is too Hot OHH M030 One of the water temp sensors has detected 118 f 47 8 C in the heater and the spa is shut down You must press any button to reset when...

Страница 23: ... 22 12 Sensor Related Messages 13 Miscellaneous Messages This message can be reset from the topside panel with any button press ...

Страница 24: ... 23 14 System Related Messages This message can be reset from the topside panel with any button press ...

Страница 25: ...eset a displayed reminder message The Ground Fault Circuit Interrupter GFCI or Residual Current Device RCD is an important safety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function...

Страница 26: ...ting means to be provided at time of installation Permanently connected Connect only to a circuit protected by a Class A Ground Fault Circuit Interrupter GFCI or Residual Current Device RCD mounted at least 5 1 52M from the inside walls of the spa hot tub and in line of sight from the equipment compartment CSA enclosure Type 2 Refer to Wiring Diagram inside the cover of the control enclosure Refer...

Страница 27: ...ions Warning The equipment and controls shall be located not less than 1 5 meters horizontally from the spa or hot tub Warning GFCI or RCD Protection The Owner should test and reset the GFCI or RCD on a regular basis to verify its function Warning Shock Hazard No User Serviceable Parts Do not attempt service of this control system Contact your dealer or service organization for assistance Follow a...

Страница 28: ... 27 ...

Страница 29: ...tton press is indicated Ignore the direction reversal paragraph 3 JETS 1 operation with circ pump Press JETS once to turn circ pump on and press the button again to turn massage pump surfing pump on Circ pump at work cannot be turn on but massage pump surfing pump can The heater and ozone work together with the circ pump Surfing pump massage pump at work will turn off after 15 minutes Circ pump wi...

Страница 30: ...rnoff See your dealer for details 3 Diagnostic Messages Message Meaning Action Required No message on display The control panel will be disabled until power returns Spa settings will be preserved until next power up Temperature unknown After the pump has been running for 2 minutes the temperature will be displayed Overheat The spa is shut down One of the sensors has detected118 F 48 C at the heate...

Страница 31: ... Press any button to reset Ⅲ Brief Introduction of All SPA Models 1 Materials Spa models are made of acrylic plate with fiber glass reinforced Color of Acrylic A010 White cloud A020 Pearl black WT6064 white etc 2 Functions Water massage Air bubble Heating Circulation Ozone sterilization FM radio Bottom LED lights Control panel Plastic Hem skirt etc 3 Options Cover Stair Heat insulation on tub body...

Страница 32: ...omatic perfume etc Ⅳ Description on Using Parts A MANUAL OF THE WATERPROOF BLUETOOTH AMPLIFIER SYSTEM Configuration 1 Waterproof speakers 2pcs 30 50W 2 Bluetooth amplifier 1pc Equipment parameters 1 Power input 2100 240V 50 60Hz 1 0A 2 Power output sound channel 2 0 2 15W 4Ω 3 Bluetooth version V4 2 4 Frequency response 20Hz 20kHz 5 Water proof IPX5 The wiring diagram 6 Connected to the load and p...

Страница 33: ...t filters daily maintenance Type one 1 Remove the outer cover of the skimmer 2 Pull out the skimmer screw 3 Take out the paper core 4 Wash the paper core with water reset it after cleaning and dry out Type two 1 Pull apart the crystal package of the paper core 2 Pull out the cover of filtration bucket 3 Match the paper core inside and screw it tight then put the cover of filtration bucket back Typ...

Страница 34: ...one and tear out the package of the paper core and put it inside the filtration bucket 6 Match the paper core correctly inside and screw it down in sequence then put the cover of filtration bucket on top Noted Different spa model with standard configuration will be equipped with one of these three filtrations please install and clean the paper core in accord with the proper filtration system you p...

Страница 35: ...kW 56827 02 Titanium 3kW Custom Box Overlay Box Overlay Part Number N A CE System Model For 3 0kW BP21 BP6013G2 RCA3 0K Software Version ID M100_226 V37 0 Software Version 37 0 File Name BP6013_37 0_BP6013G2 hex Configuration Signature F71FE5EB Eng Project Number 4890 Control Panels TP600 Version 2 7 and later Version 2 12 or later required for bba bba 2 On Off control via menu TP400T CE Version 2...

Страница 36: ... 35 Diagram of 220V 230V L N E Diagram of 380V L N E 2 control system GS100 GS500 Panels VL260D panel Electric box GS500Z ...

Страница 37: ...ith acetone solution ammonia water and organic solvent otherwise it may possibly damage the surface of the bathtub Mildly wipe off the adhesive stains on the bathtub with soft fabric and gasoline 2 If there s scratches on the bathtub please grind with 2000 grinding paper with water and then polish with toothpaste and soft fabric 3 Please wipe off the water scale on the bathtub with light acid dete...

Страница 38: ...side plate of the bathtub 3 Replace the thermostat cut off power supply open the bathtub side plate turn off the valves on both ends of thermostat remove the wires loosen the fixed bolts and take out the thermostat after replacement install power wire fix the bolts put into small amount of water into the bathtub turn on the valve check if there s leakage at the pump and then install the side plate...

Страница 39: ...oa control system SPA control system is found to be defective in the field the RMA can be handled either through the OEM or through one of Balboa offices In all cases the OEM dealer distributor is encouraged first to call one of the Balboa tech service departments to get assistance in troubleshooting the product and diagnose the problem In Europe Balboa warranty department can be reached at HYDROA...