Balboa ML700 Скачать руководство пользователя страница 10

Page 8

GFCI Protection

Your spa may be equipped with a GFCI Protection 
feature. If your spa does have this feature enabled, the 
GFCI Trip Test must occur to allow proper spa function.

Within 1 to 7 days after startup, the spa will trip 
the GFCI to test it. (The number of days is factory 
programmed.) The GFCI must be reset once it has been 
tripped. After passing the GFCI Trip Test, subsequent 
GFCI trips will indicate a ground fault or other unsafe 
condition requiring the power to the spa to be shut off.

GFCI Trip Test Procedure

The installer can cause the GFCI Trip Test to 
occur sooner by initiating it with the following 
button sequence.

Press “Warm”, then “Jets 1”, then “Light.” (Each press 
must be within 3 seconds of the previous press.) Press 
the “Warm” button repeatedly until “

” is displayed. 

Press “Jets 1” to select it. Press the “Warm” button until 

” is displayed. Press “Jets 1” to initiate the GFCI 

Trip Test.

The GFCI should trip within several seconds and the spa 
should shut down. If it does not, shut down the power 
and manually verify that a GFCI breaker is installed and 
that the circuit and spa are wired correctly. Verify the 
function of the GFCI with its own test button. Restore 
power to the spa and repeat the GFCI Trip Test.

Once the GFCI is tripped by the test, reset the GFCI and 
the spa will operate normally from that point. You can 
verify a successful test by navigating to the “

” item 

as described above, pressing “Jets 1” and then pressing 
the “Warm” button until you see “

”. The code 

signifies GFCI Status - Passed.

The system will exit this menu in 30 seconds if no 
buttons are pressed.

Periodic Reminder Messages 

(Press the “Mode” button to reset a displayed reminder.*)

Message **

Frequency ***

Action Required

Every 7 days

Test and adjust pH chemical levels per manufacturer’s instructions.

Every 7 days

Test and adjust sanitizer chemical levels per manufacturer’s instructions.

Every 30 days Remove, clean, and reinstall filter per manufacturer’s instructions.

Every 30 days Test & reset GFCI per manufacturer’s instructions.

Every 90 days Drain and refill spa per manufacturer’s instructions.

Every 180 days Clean and condition cover per manufacturer’s instructions.

Every 180 days Clean and condition wood per manufacturer’s instructions.

Every 365 days Install new filter.

As needed

Install new Mineral cartridge.

* User can suppress all reminders in User Preferences.

** All of these Periodic Messages can be disabled individually by the spa manufacturer.

*** Any of these frequencies may be changed by the spa manufacturer.

Warning: 

The Owner should test and reset the GFCI 

on a regular basis to verify its function.

Note:

The GFCI section does not apply on EL systems used outside the United States.

This GFCI section does not apply to GL Systems.

Содержание ML700

Страница 1: ...t Jets 1 F2 TL F1 PL 900854 ML700 User Guide EL GL Series Mach 3 Note regarding EL and GL systems Mach 3 EL and GL systems function identically but conform to different International requirements This user guide will refer to EL systems for the sake of simplicity but the information given applies to both EL and GL products ...

Страница 2: ......

Страница 3: ...in sequence they may not register Table of Contents EL GL SERIES Mach 3 CONTROL 1 Initial Start up 1 Icon Legend 1 Time 2 Setting the Time 2 Temp Set 2 Warm Cool 2 Mode Prog 2 Standby Mode 2 Jets 1 2 Jets 2 3 Blower 3 Invert 3 Preset Filter Cycles 3 Optional Filter Cycle Programming 3 Light 4 Freeze Protection 4 Locking the Panel 4 Locking the Set Temperature 4 Clean up Cycle 4 Circ Pump 4 Ozone 4...

Страница 4: ...tton resets the spa On some systems the Jets 1 button will control the pump in Standby Mode Drain Mode In this case press any other button to exit System will revert to previous mode after 1 hour Jets 1 Press the Jets 1 button once to turn pump 1 on or off and to shift between low and high speeds if equipped If left running the pump will turn off after a timeout period The pump 1 low speed timeout...

Страница 5: ...ilter cycle night begins 12 hours later Filter duration is programmable for 1 12 hours The default filter duration can vary from system to system To program press Warm or Cool then Jets 1 Press Warm or Cool to select the filter duration Press Jets 1 to select the number of filter cycles The display will show both day and night cycles day cycle only or night cycle only Press Warm or Cool to adjust ...

Страница 6: ... dealer for details Locking the Panel Press Time Jets 1 then Warm within 3 seconds When locked the PL PL light will light All buttons are frozen except the Time button To unlock the panel press Time Jets 1 then Cool Locking the Set Temperature Press Warm or Cool then Time Jets 1 and Warm within 3 seconds to activate the lock The TL TL light will light when the set temperature is locked On some sys...

Страница 7: ...24 hour military format 00 00 is midnight 23 00 is one hour before midnight When set to time is displayed in 12 hour am pm format 12 00 is midnight 11 00 pm is one hour before midnight Clean up Cycle Duration some systems only When set to Clean up Cycles are disabled When set to through the number indicates how many hours each Clean up Cycle will run Dolphin II Address When set to no addressing is...

Страница 8: ...nce the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and allow water to cool At 107 F approximately 41 7 C the spa should automatically reset If spa does not reset shut off the power to the spa and call your dealer or service organization No action required ...

Страница 9: ...nt spa temperature either switch to Standard mode or turn Jets 1 on for at least 1 minute Press any button except Jets 1 to leave Standby Mode and return to normal operation Add pH increaser according to manufacturer s instructions Add pH reducer according to manufacturer s instructions Add sanitizer according to manufacturer s instructions Remove spa cover and allow sanitizer to dissipate Press J...

Страница 10: ...st reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the item as described above pressing Jets 1 and then pressing the Warm button until you see The code signifies GFCI Status Passed The system will exit this menu in 30 seconds if no buttons are pressed Periodic Reminder Messages Press the Mode button to reset a displayed reminder Me...

Страница 11: ...n to raise and lower the TV Lift device There is no timeout for this feature Fiber optional on some systems If a fiber optic light with wheel is installed press the Fiber button once to start the light and wheel press it again to stop the wheel and then again to turn the light off The fiber icon stands still when the fiber optic light is on by itself and rotates when the color wheel is also on Bot...

Страница 12: ...he spa Read the instruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a Class A ground fault circuit interrupter To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitably rated suction guard to ma...

Отзывы: