background image

YXcYfX$`ejkild\ekj%Zfd

Cool

Warm

Time

Mode/Prog

Jets 2

Light

Jets 1

F2

TL

F1

PL

Cool

Warm

Time

Mode/Prog

Blower

Jets 2

Light

Jets 1

F2

TL

F1

PL

900854

ML700 User Guide

    EL/GL Series - Mach 3

Note regarding EL and GL systems: Mach 3 EL and GL systems function 
identically, but conform to different International requirements. This 
user guide will refer to EL systems for the sake of simplicity, but the 
information given applies to both EL and GL products.

Содержание ML700

Страница 1: ...t Jets 1 F2 TL F1 PL 900854 ML700 User Guide EL GL Series Mach 3 Note regarding EL and GL systems Mach 3 EL and GL systems function identically but conform to different International requirements This user guide will refer to EL systems for the sake of simplicity but the information given applies to both EL and GL products ...

Страница 2: ......

Страница 3: ...in sequence they may not register Table of Contents EL GL SERIES Mach 3 CONTROL 1 Initial Start up 1 Icon Legend 1 Time 2 Setting the Time 2 Temp Set 2 Warm Cool 2 Mode Prog 2 Standby Mode 2 Jets 1 2 Jets 2 3 Blower 3 Invert 3 Preset Filter Cycles 3 Optional Filter Cycle Programming 3 Light 4 Freeze Protection 4 Locking the Panel 4 Locking the Set Temperature 4 Clean up Cycle 4 Circ Pump 4 Ozone 4...

Страница 4: ...tton resets the spa On some systems the Jets 1 button will control the pump in Standby Mode Drain Mode In this case press any other button to exit System will revert to previous mode after 1 hour Jets 1 Press the Jets 1 button once to turn pump 1 on or off and to shift between low and high speeds if equipped If left running the pump will turn off after a timeout period The pump 1 low speed timeout...

Страница 5: ...ilter cycle night begins 12 hours later Filter duration is programmable for 1 12 hours The default filter duration can vary from system to system To program press Warm or Cool then Jets 1 Press Warm or Cool to select the filter duration Press Jets 1 to select the number of filter cycles The display will show both day and night cycles day cycle only or night cycle only Press Warm or Cool to adjust ...

Страница 6: ... dealer for details Locking the Panel Press Time Jets 1 then Warm within 3 seconds When locked the PL PL light will light All buttons are frozen except the Time button To unlock the panel press Time Jets 1 then Cool Locking the Set Temperature Press Warm or Cool then Time Jets 1 and Warm within 3 seconds to activate the lock The TL TL light will light when the set temperature is locked On some sys...

Страница 7: ...24 hour military format 00 00 is midnight 23 00 is one hour before midnight When set to time is displayed in 12 hour am pm format 12 00 is midnight 11 00 pm is one hour before midnight Clean up Cycle Duration some systems only When set to Clean up Cycles are disabled When set to through the number indicates how many hours each Clean up Cycle will run Dolphin II Address When set to no addressing is...

Страница 8: ...nce the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and allow water to cool At 107 F approximately 41 7 C the spa should automatically reset If spa does not reset shut off the power to the spa and call your dealer or service organization No action required ...

Страница 9: ...nt spa temperature either switch to Standard mode or turn Jets 1 on for at least 1 minute Press any button except Jets 1 to leave Standby Mode and return to normal operation Add pH increaser according to manufacturer s instructions Add pH reducer according to manufacturer s instructions Add sanitizer according to manufacturer s instructions Remove spa cover and allow sanitizer to dissipate Press J...

Страница 10: ...st reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the item as described above pressing Jets 1 and then pressing the Warm button until you see The code signifies GFCI Status Passed The system will exit this menu in 30 seconds if no buttons are pressed Periodic Reminder Messages Press the Mode button to reset a displayed reminder Me...

Страница 11: ...n to raise and lower the TV Lift device There is no timeout for this feature Fiber optional on some systems If a fiber optic light with wheel is installed press the Fiber button once to start the light and wheel press it again to stop the wheel and then again to turn the light off The fiber icon stands still when the fiber optic light is on by itself and rotates when the color wheel is also on Bot...

Страница 12: ...he spa Read the instruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a Class A ground fault circuit interrupter To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitably rated suction guard to ma...

Отзывы: