Power Requirements:

Single Service 

[3 wires (line, neutral, ground)] 

230VAC, 50/60Hz*, 1þ, 16A, (Circuit Breaker rating = 20A max.)

Single Service 

[3 wires (line, neutral, ground)] 

230VAC, 50/60Hz*, 1þ, 32A, (Circuit Breaker rating = 40A max.)

2-out-of-3-Service 

[4 wires (line 1, line 2, no line 3, neutral, ground)]  

230VAC line-to-neutral**, 50/60Hz*, 2/3þ, 16A, (Circuit Breaker rating = 20A max each phase line.)
NOTE:  2-out-of-Service is simply 3-Service (single common) with one of the three lines unused.  The third line could be used for a slave heater if desired, or left for a use not 
related to the spa at all.

 

 

 

 

*BP systems automatically detect 50Hz vs 60Hz.  However, power frequency (50Hz vs 60Hz) is just one of many differences between North American (UL) and CE power, and it is 

because of these other differences that different BP systems must be used for UL vs CE territories.  Also, there are a few countries that use CE power but 60 Hz (such as South 
Korea) which need CE systems, and a few countries that use UL power but 50 Hz which need UL systems.

** 3-phase service measured line-to-line will read about 400V, but BP systems do not use it line-to-line.

IMPORTANT -

 Service must include a neutral wire, with a line to neutral voltage of 230VAC.

 

Basic Functions Setup 1 - 7

HiPot Testing Note:

Disconnect slip terminal with green
wires from J6 prior to performing
HiPot test. Failure to disconnect may
cause a false failure of the test.
Reconnect terminal to J6 after
successful completion of HiPot test.

Содержание 59340-01

Страница 1: ...ID M100_235 V52 0 Software Version 52 0 File Name BP200_52 0_BP200UX hex Configuration Signature AE7D76E4 Eng Project Number 5270 Control Panels See later pages for more information spaTouch 2 Any ver...

Страница 2: ...with an optional user insstalled expander board the expander board mounting hardware is pre installed 59340 01 59342 01 5270 09 05 19 BWG Update software for full TP500 compatibility 59310 5270 09 05...

Страница 3: ...of the three lines unused The third line could be used for a slave heater if desired or left for a use not related to the spa at all BP systems automatically detect 50Hz vs 60Hz However power frequenc...

Страница 4: ...mp at high speed prevents you from turning the other pump to high speed You have to turn the first pump to either low speed or OFF before you can turn the other pump to high speed 2 out of 3 Service w...

Страница 5: ...P1 Low in non circ Setupa 2 4 6 only This is the heater pump in Setups 2 4 6 Must deliver 20 GPM through heater 1 Speed in Setups 1 3 5 Unused in Setup 7 Pump 2 230VAC 1 Speed 12A max 15 minute timer...

Страница 6: ...AREA 3 CONNECT TO J5 F5 10A 250V 1 FILTERS POLLING 1 SPEED 1 SPEED NONE X P2151 PN 59233 C 2 NONE 2 SPEED 1 SPEED NONE X P2151 PN 59233 C 3 FILTERS POLLING 1 SPEED NONE 1 SPEED X B PN 59231 C 4 NONE 2...

Страница 7: ...ING 1 SPEED 1 SPEED NONE X P2151 PN 59233 C 2 NONE 2 SPEED 1 SPEED NONE X P2151 PN 59233 C 3 FILTERS POLLING 1 SPEED NONE 1 SPEED X B PN 59231 C 4 NONE 2 SPEED NONE 1 SPEED X B PN 59231 C 5 FILTERS PO...

Страница 8: ...A2 A5 ON OFF 230V 1 1x16A As shown on additional wiring diagram sections 1 2 J4 J8 J18 J51 J1 J27 J10 3 J20 J10 J12 J88 J52 230V 2 3 2 3x16A A2 A3 ON OFF A5 A8 A2 A3 ON OFF A5 A8 FOR PUMP2 OR BLOWER O...

Страница 9: ...o Change Software Setups While in Test Mode press the indicated icons to move from screen to screen ON 1 10 S1 Changing Software Setups with spaTouch Icon Driven Panels Once on the Setup Selection scr...

Страница 10: ...em is running move DIP Switch 1 on S1 on the Main circuit board to ON The system will enter Test Mode Moving DIP Switch 1 to OFF will exit Test Mode Software Setups Under the TEST Menu the Setup scree...

Страница 11: ...oving DIP Switch 1 to OFF will exit Test Mode Software Setups Under the TEST Menu the Setup screen will allow changing the Setup from 1 to any number established by the Manufacturer Changing the Setup...

Страница 12: ...ace a circuit board or system and needs to change the Setup on a replacement part while in the field NOTE Changing the Setup may require wiring changes as well refer to the wiring diagram or wiring di...

Страница 13: ...188 6976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending Copyright 2009 Balboa Water Group Expansion F...

Страница 14: ...etermined by software configuration A2 and A3 work in combination to determine the number of high speed devices and blowers that can run before the heat is disabled i e A2 and A3 in the ON position wi...

Страница 15: ...models J30 Do Not Use J31 Jumper on 1 pin with 2 0kW or smaller heater Jumper on 2 pins with a 3 0kW or higher heater J44 Jumper must be on center two pins 240V for CE Systems Warning Setting DIP swi...

Страница 16: ...9341 01 3 0kW Models 59343 01 2 0kW Models Remote Model Expander PCBA 59233 X P2151 for Pump2 59231 X B for Blower HEATER s Heater 58419 3 0kW 800 Inc for integral heater only 58450 3 0kW 825 Inc for...

Страница 17: ...nly General Pump Timer 15 Minutes Blower Timer 15 Minutes Mister Timer 15 Minutes Light Timer 240 Minutes Circ when enabled Programmable Polling Circ Pump can be set with the following functions 24 hr...

Страница 18: ...ired for default settings choose a desired C value that after rounding cor responds to a Fahrenheit value C 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 F 39 41 43 45 46 48 50 52 54 55 57 59 61...

Страница 19: ...me Format 24 Hour 12 Hour 24 Hour N A Filter 1 Start Hour 20 00 8 00 PM 00 00 to 23 00 1 Hour Filter 1 Duration 2 Hours Between 15 Min and 23 45 15 Minutes or continuous Filter Cycle 2 Default OFF OFF...

Страница 20: ...ment Reminders Shown Yes Yes No N A Check pH OFF See Reminder Period Note 1 Days Check Sanitizer OFF See Reminder Period Note 1 Days Clean Filter 30 Days See Reminder Period Note 1 Days Test GFCI OFF...

Страница 21: ...B 1 Pump at High Speed maximum Blower turns OFF when 1 Pump is at High Speed 3 Phase Special Amperage Rule Pumps or Blower in Group 3 eg Pump 2 are the only ones which turn the Heater Off Pumps not in...

Страница 22: ...ert Invert Circ Icon 5 Invert Invert Invert Invert Circ Icon Undefined Undefined 6 Circ Icon Undefined Circ Icon Undefined Undefined Undefined Undefined 7 Undefined Undefined Undefined Undefined Undef...

Страница 23: ...Icon Undefined A6 Circ Icon Undefined Circ Icon Undefined Undefined Undefined A7 Undefined Undefined Undefined Undefined Undefined Undefined A8 Undefined Undefined Undefined Undefined Undefined Undef...

Страница 24: ...976052 6965815 7030343 7 417 834 b2 Canadian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending Copyright 2009 Balboa Water Group TP800 Panel Conf...

Страница 25: ...domestic applied for and pending Copyright 2009 Balboa Water Group TP600 Panel Configuration READY RANGE FLTR1 1 2 3 4 5 6 1 2 3 4 1 2 3 4 1 4 2 5 3 6 TP600 55676 XX No Overlay Button Layout Table Bu...

Страница 26: ...260 XX Includes overlay PN 12511 Button Layout Table for TP400T Button Setups 1 2 Setups 3 4 Setups 5 6 Setup 7 1 Temperature Temperature Temperature Up 2 Jets 1 Jets 1 Jets 1 Down 3 Light 1 Light 1 L...