PUMP APPLICATION 

 

 

 

 

WARNING

The Balboa Hydromassage pumps have been specifically 
designed for use in spa baths (whirlpools). They should 
not be used for any other purpose without first consulting 
your Balboa dealer or Balboa representative. 

The Balboa Hydromassage pump is NOT a self priming 
pump. Ensure there is sufficient water to completely 
fill the pump casing (flood suction) before operating 
the pump. 

PUMP POSITION 

 

 

 

 

WARNING

To avoid water damage to property from leaking 
connections or normal wear, the pump must be installed 
on a well drained site or a properly constructed drain tray. 

If the pump is supplied separately to the spa bath, 
position the pump as close as possible to the spa. This 
will ensure optimum spa jet performance. 

PUMP INSTALLATION

The pump mount must be Solid – Level – Rigid – 

t

Vibration free (to reduce vibration and pipe stress, 
bolt the pump to the pump mount). 
Install the pump suction inlet higher than bath suction 

t

fitting (refer to Fig 1). This allows the pump to drain 
completely when the bath is emptied in accordance 
with Local Health Regulations.
Ensure suction pipe has an even rise from the spa 

t

bath (whirlpool spa) suction inlet to avoid air locks, 
otherwise the spa pump may not prime, Fig. 1.
Ensure discharge pipe has an even rise from the 

t

pump to the spa bath (whirlpool) connection to avoid 
air locks.
Protect pump from excess moisture, external weather 

t

(where applicable). 
Allow adequate access for servicing pump 

t

and piping. 

VENTILATION

Provide adequate ventilation to prevent the motor 

t

from overheating (minimum distance is 102 cm). 
Without adequate ventilation the pump motor may 
overheat causing the pump to stop.
The hydromassage pumps must be protected from 

t

exposure to the weather. If the pump is installed 
outside, a protective cover is required.

 
PIPING

WARNING

The fittings on these hydromassage pumps are 
constructed of ABS. Some PVC jointing compounds are 
incompatible with ABS possibly causing failure to the 
product. Check compound suitability prior to use.

For best pump efficiency use the least amount 

t

of fittings. 
Balboa hydromassage pumps are supplied complete 

t

with integrated multi-directional (40mm) barrel unions 
to allow easy installation of pipework. Use as follows 
for leak-free connections to pump: 

O-Ring and sealing surfaces must be clean. 

1. 

Ensure O’Ring remains on barrel unions and tighten 

2. 

HAND TIGHT only! (NO WRENCHES) 
No pipe compound or teflon tape on unions. 

3. 

Bond pipe to unions with a compatible PVC 

4. 

solvent cement. 
 When appropriate, fill the bath with water and check 

5. 

that there are no visible leaks from the plumbing 
joints. Start the pump and repeat this step. 

AIR BLEED VALVE

Air bleed valves are sometimes required on installations 
so that automatic air venting can occur.  
 
Balboa 200 Series Hydromassage pumps are fitted with 
an air bleed valve. If the pump is installed exactly per Fig. 
1,  this valve will not be required to be made functional 
(the air bleed valves are sealed at the manufacturer).  
 
If automatic air venting is required, cut the top of the 
valve off at the cut groove found approximately 3.5mm 
from top of the valve per Fig. 2 using a pair of side 
cutters. DO NOT USE PLIERS. The air bleed valve will not 
expel air.  
 
As it is common for air valves to squirt water when sealing 
(each time the pump is turned on), Balboa recommends 
that a 10mm drain tube to be fitted over the barbed 
section of the air bleed valve to allow excess water to 
drain to waste.  Refer to Fig. 2. 

AIR VENTURI CONTROL

TO WASTE

Fig. 1

SPA SUCTION LINE MUST HAVE 
GRADIENT RETURNING TO DRAIN

SPA SURROUND

Содержание 2374

Страница 1: ...Balboa 200 Series Electronic Hydromassage Pumps Models 2374 2394 and 2404 Hot Pump Bathmaster Models 2376 2386 2396 and 2406 DR Pump without heater Models 2377 2387 2397 and 2407 DR Pump with heater T...

Страница 2: ...u will not and will not attempt to modify prepare derivative works of reverse engineer decompile disassemble or otherwise attempt to create source code from the software No title to or ownership in th...

Страница 3: ...must be protected from t exposure to the weather If the pump is installed outside a protective cover is required PIPING WARNING The ttings on these hydromassage pumps are constructed of ABS Some PVC...

Страница 4: ...ouch pad and a 6 metre signal cable to control the pump and heater functions Assembly 2374 2394 2404 Click the escutcheon onto the touch pad Then apply the decal label to the face of the touch pad ens...

Страница 5: ...has 2 or 3 buttons on it JETS button turns on off the pump and 1 integrated heater HEAT button enables the heater to be turned on 2 off whilst the pump is running If equipped with an optional blower...

Страница 6: ...mage to the pump from occurring as a result of the pump operating without water owing through it If at any stage during the normal operation of the pump the pump loses prime eg a blocked suction scena...

Страница 7: ...heater element This is normal in the standard pumps models 2376 2386 2396 2406 Heater Module does not operate Contact Service Technician Heater Module is too small for the capacity of the bath Con rm...

Страница 8: ...Assy 1 3 Tail and Air bleed Assy 1 11 Screws Cover 8 4 Casing 1 12 Screws Casing 4 5 Diffuser 1 13 Nuts Casing 4 6 Impeller 1 14 Base and Screws Kit 1 7A Mechanical Seal Kit 1 15 Heater Module Assy Ho...

Страница 9: ...credit department invoices may be due thirty 30 days from the date of invoice or on such other terms as approved by the company s credit department in writing The credit department may decline at any...

Страница 10: ...cation of the United Nations Convention on Contracts for the International Sale of Goods and INCOTERMS 2000 In the event a judicial proceeding is necessary the sole forum for resolving disputes arisin...

Страница 11: ...me and address The serial number if applicable Freight is at sender s expense unless otherwise authorized by BWG A 50 USD 40EUR hourly fee plus reimbursement of all shipping expenses if applicable wil...

Страница 12: ...cannot be processed d If the product is under warranty and can not be rectified over the phone the representative will determine if the product qualifies for warranty service or warranty part replace...

Отзывы: