background image

0AGE

54751_97_B

TB1

HTR2

J101

J100

HTR1

G

N

J50

T1

J1

J2

J10

JJ

J58

J58

J71

J46

J46

J25

5

J2

66

J72

72

J90

J90

J28

8

J28

J1

A

J2A

J32

2

J52

J51

J

F6, T30A 480V

AV

OZONE

PUMP 1

OPT. BLWR/PUMP 2

CIRC. PUMP

K1

K3

K4

K6

E.GND

E

.GND

J47

G

N

G

N

G

N

J29

J23

G

N

J17/26

K2

K9

J20

G

N

W2

1

2

3

4

W1

Balboa

BALBOA INSTRUMENTS, INC.
GS500Z
COPYRIGHT 2006
MADE IN U.S.A.
P/N 22015_A

J60

J44

J18

1

1

1

1

1

1

1

J7

J8

EXT RLY

TST

J6

SEN A

VAC

SEN B

J22

J43

AUX F

J13

J11

J12

J19

F2

S1

SWITCHBANK A

K8

K5

C9

U4

F3A 250V

F7

F1

F10A 250V

F4, T0.3A 250V

Pbb

PPP

F3

GS5xxDZ mode

G

R

B

W

J1

1

J7

J6

F30A 480V

X-P332 CE
PN 55138

P/N 22909 REV B

2-Spd P2

1-Spd P3

3.0 kW

Heater rated @ 230V
J11 must be Jumpered

3.0kW

Spa 

Light

Audio Visual

Circ Pump

DIP switch A9 must be ON if Circ Pump is installed.

Ozone

2-Spd P1

Wiring Configuration and DIP Settings

Setup 2

s 60UMP3PEED
s 60UMP3PEED
s 60UMP3PEED

s 63PA,IGHT
s 6/ZONE
s 6!<6

(Stereo)

s 6K7(EATER
s $ELUXE-AIN0ANEL
s 6#IRC0UMPOPTIONAL 

A1, Test Mode OFF
A2, See Table 1
A3, N/A

A7, J17/26 Disabled

A10, See Table 1

A5, NA when A9 if OFF

Panel Button Assignments

1=Time
2=Mode/Prog
3=Temp Up
4=Temp Down

5=Light
6=Pump 1
7=Pump 2
8=Unused

Panel Button Positions

1

2

3

4

8

6

5

7

100

94
39

SSID #

J11

3.0kW

Heater

J12

1

2

3

GS520DZ

Software

Memory
Reset

J43

A8, Degrees C

A7, J17/26 Enabled

8=J17/26

A6, 50 Hz

A5, 2-speed P1

Neutral (Common) AC Connections

Special AC Connections

Line AC Connections

10 Volt Connections

Relay Control Wires

Wiring Color Key

Typically Line voltage

Typically Line voltage for 2-speed pumps

Neutral (Common)

Ground

Note flat sides in connector

Board Connector Key

1

2

3

4

WARNING: 

Main Power to system should be turned OFF BEFORE adjusting DIP switches.

WARNING: 

Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

H

I

Pot Testing Note:

Disconnect slip terminal with green 
wires from J90 prior to performing 
HiPot test.  Failure to disconnect may 
cause a false failure of the test.

Reconnect terminal to J90 after 
successful completion of HiPot test.

Содержание GS520DZ

Страница 1: ...pdf 10 18 2007 Template used 40599_F pdf 08 03 2007 9XcYfX ejkild ekj Jpjk d GE System Model GS5 GS520DZ RCA 3 0K Software Version 39 EPN 2552 Base PCBA PN 55847 PCB GS500Z PN 22015 Rev A Base Panels...

Страница 2: ...ystem Revision History System PN EPN Date Requested By Changes Made 54751 2552 08 22 2007 Balboa New system release 54751 2552 10 05 2007 Balboa Software update to v41 54751 2552 10 18 2007 Balboa Sof...

Страница 3: ...ES LINE NEUTRAL LINE NEUTRAL GROUND s 6 Z X IRCUIT REAKER RATING MAX EACH SERVICE System Outputs J1 J2 J10 J71 J72 72 J1A J2A J60 J44 J18 1 1 1 1 1 1 1 J7 J8 EXT RLY SEN A VAC SEN B J22 AUX F J11 J12...

Страница 4: ...t is a VS511SZ at version 38 s Displayed next is indicating the system is configured for a heater between 3 and 6 kW or indicating the system is configured for a heater effectively between 1 and 3 kW...

Страница 5: ...6 K7 EATER s ELUXE AIN 0ANEL s 6 IRC 0UMP OPTIONAL A1 Test Mode OFF A2 See Table 1 A3 N A A7 J17 26 Disabled A10 See Table 1 A5 NA when A9 if OFF Panel Button Assignments 1 Time 2 Mode Prog 3 Temp Up...

Страница 6: ...EATER s ELUXE AIN 0ANEL s 6 IRC 0UMP OPTIONAL A1 Test Mode OFF A2 See Table 1 A3 N A A7 J17 26 Disabled A10 See Table 1 A5 NA when A9 if OFF Panel Button Assignments 1 Time 2 Mode Prog 3 Temp Up 4 Te...

Страница 7: ...n 60Hz operation A7 ON position J17 26 equipment enabled OFF position J17 26 equipment disabled A8 ON position temperature is displayed in degrees Celsius OFF position temperature is displayed in degr...

Страница 8: ...2 S1 SWITCHBANK A K8 K5 C9 U4 F3A 250V F7 F1 F10A 250V F4 T0 3A 250V Pb F3 L1 N1 Single Service 1 x 16 Amp or 1 x 32 Amp This option is con gured and shipped as the default All equipment pumps blower...

Страница 9: ...rown Line Conductor Balboa Ozone connector configuration for 230VAC 50Hz L N Empty White or Blue Neutral Conductor Flat sides of sockets as shown Not used Line Black or Brown conductor Not used Neutra...

Страница 10: ...ted as custom overlays Time Warm Blower Light Mode Prog Time Warm Blower Light Cool Mode Prog Jets 1 Jets 2 VL801D Serial Deluxe PN 54108 with Overlay PN 10763 s Connects to Main Panel terminal J1 S E...

Отзывы: