Basic System Features and Functions

Any time you change a DIP Switch, other than A1, you must reset Persistent 
Memory for your new DIP Switch Settings changes to take effect. If you do 
not reset Persistent Memory, your system may function improperly.

To reset Persistent Memory:

s

  Power down by disconnecting power source from spa.

s

  Put a jumper across J43, covering both pins. (See illustration below)

s

  Power up by connecting power source to spa.

s

  Wait until “

” is displayed on your panel.

s

  Power down again.

s

  Remove jumper from J43 (May also move to cover 1 pin only)

s

  Power up again.

About Persistent Memory and Time of Day Retention:

This system uses memory that doesn’t require a battery to store a variety of 
settings.  What we refer to as Persistent Memory stores the filter settings, 
the set temperature, and the heat mode.

Persistent Memory is not used for Time of Day.  Only models with a 
Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the 
time.  However, during power loss to the spa, the system will lose the 
correct time, and reset to 12:00 PM when power is restored.

Power Up Display Sequence

Upon power up, you should see the following on the display:

s

  Three numbers in a row, which are the SSID (the System Software 

ID).  The third display of these numbers is the Software Version, 
which should match the version of your system.  For example, if these 
three numbers are 

  

  

, that is a VS511SZ at version 38.

s

  Displayed next is: “

” (indicating the system is configured for 

a heater between 3 and 6 kW) or “ ” (indicating the system is 
configured for a heater effectively* between 1 and 3 kW). 

” should appear for all VS models running at 240VAC. 

“ ” should appear for all VS models running at 120VAC, as well 
as all GS models.  (*A heater which is rated at 4 kW at 240VAC will 
function as a 1 kW heater at 120VAC.)

s

  “

” will appear to signal the start of Priming Mode.

At this point, the power up sequence is complete.  Refer to the Reference 
Card for the VS or GS System model of your spa for information about how 
the spa operates from this point on, including how to adjust the Time of 
Day if using a Serial Deluxe style panel.

G

C

G

C

G

C

G

C

C

G

T1

SWITCHBANK A

BALBOA INSTRUMENTS, INC.
VS500Z
P/N  22972 REV D

MADE IN U.S.A

COPYRIGHT 2005

S1

J6

J7

J8

J44

J60

J22

U4

FUSE .3A 250V

FUSE 20A 250V

F

US

E 3A 250

V

E.

G

ND

F4

K6

K1

K8

K9

K5

J23

J46J46

F1

J29

J47

J50

F7

J17

/26

J20

J1A

J10

J13

J2A

EXT.

T

T

RLY

L

L

TST

AUX. F

SEN. A

SEN. B

VAC

V

V

W1

W7

J1

J2

W2

W3

G

C

W

4

K2

K3

F2

J12

1

2 3

J43

2-SPD

EXT RLY

J1

8

SWITCHBANK A

S1

J6

E.GND

TST

J43

J43 on VS5xxZ and VS300 Series Main Board Shown.
J43 on GS5xxZ Series is located in approximately the same position.

G

C

SWITCHBANK A

P

/N 22964_B

M

ADE IN

U

.S

.A.

VS100

© 200

6

S1

K3

K5

K4

K1

PUMP

K

2

J7

J8

U4

T0.25A 250V

F2

J23

G

C

OZONE

J29

HEATER

A

A

J9

J20

TST

RST

SEN. A

SEN. B

J1

B

albo

a

F4

J43

J6

G

C

F5, F3A 250V

J26

J58

J57

J50J50

J13J13

J12J12

J90J90

LINE

NEUTRAL

NEUTRAL

WHT AC

BLK AC

W1

J18

SWITCHBANK A

TST

RST

J43

J6

J43 on VS100/GS100 Series Main Board Shown.

Содержание GS520DZ

Страница 1: ...pdf 10 18 2007 Template used 40599_F pdf 08 03 2007 9XcYfX ejkild ekj Jpjk d GE System Model GS5 GS520DZ RCA 3 0K Software Version 39 EPN 2552 Base PCBA PN 55847 PCB GS500Z PN 22015 Rev A Base Panels...

Страница 2: ...ystem Revision History System PN EPN Date Requested By Changes Made 54751 2552 08 22 2007 Balboa New system release 54751 2552 10 05 2007 Balboa Software update to v41 54751 2552 10 18 2007 Balboa Sof...

Страница 3: ...ES LINE NEUTRAL LINE NEUTRAL GROUND s 6 Z X IRCUIT REAKER RATING MAX EACH SERVICE System Outputs J1 J2 J10 J71 J72 72 J1A J2A J60 J44 J18 1 1 1 1 1 1 1 J7 J8 EXT RLY SEN A VAC SEN B J22 AUX F J11 J12...

Страница 4: ...t is a VS511SZ at version 38 s Displayed next is indicating the system is configured for a heater between 3 and 6 kW or indicating the system is configured for a heater effectively between 1 and 3 kW...

Страница 5: ...6 K7 EATER s ELUXE AIN 0ANEL s 6 IRC 0UMP OPTIONAL A1 Test Mode OFF A2 See Table 1 A3 N A A7 J17 26 Disabled A10 See Table 1 A5 NA when A9 if OFF Panel Button Assignments 1 Time 2 Mode Prog 3 Temp Up...

Страница 6: ...EATER s ELUXE AIN 0ANEL s 6 IRC 0UMP OPTIONAL A1 Test Mode OFF A2 See Table 1 A3 N A A7 J17 26 Disabled A10 See Table 1 A5 NA when A9 if OFF Panel Button Assignments 1 Time 2 Mode Prog 3 Temp Up 4 Te...

Страница 7: ...n 60Hz operation A7 ON position J17 26 equipment enabled OFF position J17 26 equipment disabled A8 ON position temperature is displayed in degrees Celsius OFF position temperature is displayed in degr...

Страница 8: ...2 S1 SWITCHBANK A K8 K5 C9 U4 F3A 250V F7 F1 F10A 250V F4 T0 3A 250V Pb F3 L1 N1 Single Service 1 x 16 Amp or 1 x 32 Amp This option is con gured and shipped as the default All equipment pumps blower...

Страница 9: ...rown Line Conductor Balboa Ozone connector configuration for 230VAC 50Hz L N Empty White or Blue Neutral Conductor Flat sides of sockets as shown Not used Line Black or Brown conductor Not used Neutra...

Страница 10: ...ted as custom overlays Time Warm Blower Light Mode Prog Time Warm Blower Light Cool Mode Prog Jets 1 Jets 2 VL801D Serial Deluxe PN 54108 with Overlay PN 10763 s Connects to Main Panel terminal J1 S E...

Отзывы: