3
1. INSTALLATION INSTRUCTIONS
SECTION
ITEM
PAGE
A
Safety Precautions
3
B
Unpacking Instructions
4
C
Gas Connection
4
2. LIGHTING INSTRUCTIONS
SECTION
ITEM
PAGE
A
Lighting Instructions
4
B
Shutdown Instructions
4
GAS SPECIFICATIONS
Propane Gas Natural Gas
BTU/HR @ 10” W.C. BTU/HR @ 3.5” W.C.
Model Number
XOB-212, XOB-212SU
XOB-424, XOB-424S
XOB-636, XOB-636SU
XOB-848, XOB-848SU
60,000
60,000
120,000
120,000
180,000
180,000
240,000
240,000
1. INSTALLATION INSTRUCTIONS
A.
SAFETY PRECAUTIONS
FOR YOUR SAFETY, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE FOLLOWED
AND ENFORCED.
IF YOU SMELL GAS:
SHUT OFF GAS SUPPLY TO APPLIANCE
EXTINGUISH OPEN FLAMES
·
IMMEDIATELY CALL YOUR GAS SUPPLIER
Instructions must be posted in a prominent location. All safety precautions must be taken in the event the
user smells gas. Safety information can be obtained from your local gas supplier.
1. A separate gas shut-off valve must be installed in the gas line ahead of the unit, as required by
codes.
2. LIGHTING: Follow the instructions on page 4.
3. At least 24 inches must be provided at the front of for servicing.
4. When installing, never enclose the bottom area of the unit with a raised curb or other
construction that would obstruct the flow of air into the unit.
5. This unit may be operated with 0” (sides and back) minimum clearance to non-combustible
construction in areas that are non-combustible locations only.
6. This installation must conform to local codes, or in absence of local codes to the
National Fuel
Gas Code ANSI Z223.1/NFPA 54
, latest edition. In Canada it must conform to current
Natural
Gas Installation Code CAN/CGA B 149.1
(natural gas) or
CAN/CGA B 149.2 Propane
Installation Code for Gas Burning Appliances & Equipment.
7. The appliance and its individual shut-off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of ½ psi (3.45
In MASSACHUSETTS:
All gas products must be installed by a “Massachusetts” licensed plumber or
gas fitter. Ventilation hoods must be installed in accordance with NFPA-96, current edition, with
interlocks as described in that standard.
CONTENTS
3. MAINTENANCE INSTRUCTIONS
SECTION
ITEM
PAGE
A
Cleaning Instructions
5
B
Maintenance Instructions
5
C
Troubleshooting Chart
5
D
Parts List & Exploded View
6
4. WARRANTY
8
All manuals and user guides at all-guides.com