1.
Check to see if the main circuit breaker is ON at the breaker panel.
2.
Check the (2) 5-amp fuses located in the bottom of the Power Control Box
3.
Check that the Main Switch is ON. If operating properly, the rocker switch will be lighted
when ON.
4.
Check the setting of the temperature control thermostats (knobs). If operating properly, they
will activate the amber indicator lights as you turn the knobs back and forth, calling for heat. It
is very unlikely that the light will burn out.
5.
If there is no air blowing, check the following:
:
the unit by turning the Main Switch OFF
for at east15 seconds and then turning it back ON. This resets the blower speed
controls. If this is not successful, turn off the wall circuit breaker for one minute and
then turn it on again.
: Observing the
at the beginning of this
section, open the Power Control Box and locate the overload relay (above
gearmotor).
. Try the Main Switch again.
1.
NOTE:
, meaning that if one or both of the blower motors get jammed, the
overload relay shuts the motor(s) OFF if there is excessive current going to
the motor(s), or if excessive heat builds up in the overload relay due to an
overload condition. Because it takes time for the relay to cool down, do not
assume that there is another problem IF pushing the RESET button doesn't
accomplish the task Both settings,
, must be correct for proper operation.
If the conveyor belt does not move, check to see that the coupling setscrew is tight on the
gearmotor output shaft.
If the oven still does not operate, turn OFF the Main Switch and disconnect the power supply to the
unit (if possible). Contact the factory, factory representative, or an authorized service agency.
.
.
i.
RESET
ii.
PUSH IN THE RESET BUTTON
The Overload Relay is both a current limiting and a thermal
device
RESET button pushed IN & overload
not overheated
6.
CAUTION
IF FUSES ARE BAD, REPLACE ONLY WITH IDENTICAL FUSES.
DO NOT
SUBSTITUTE HIGHER VALUE FUSES, AS THIS MAY NULLIFY NEEDED PROTECTION
FOR THE INTERNALELECTRICALCOMPONENTS.
DUALAIR MODEL VHVA-SERIES
DUAL AIR MODEL VH-SERIES
WARNING
ALL SERVICING SHOULD BE PERFORMED ONLY BY A FACTORY AUTHORIZED SERVICE
TECHNICIAN ORAGENT
:
12. RATING PLATE
A copy of the rating plate is shown here for reference.
MODEL VH-SERIES
MODEL VHVA-SERIES