background image

2  |  

Baker Hughes

© 2021 Baker Hughes Company. All rights reserved.

THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT 

PROJECT-SPECIFIC REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/

OPERATOR’S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE 

OPERATION AND MAINTENANCE PHILOSOPHIES VARY, BAKER HUGHES COMPANY 

(AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC 

PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY 

THE TYPE OF EQUIPMENT PROVIDED. 
THESE INSTRUCTIONS ASSUME THAT OPERATORS ALREADY HAVE A GENERAL 

UNDERSTANDING OF THE REQUIREMENTS FOR SAFE OPERATION OF MECHANICAL AND 

ELECTRICAL EQUIPMENT IN POTENTIALLY HAZARDOUS ENVIRONMENTS. THEREFORE, 

THESE INSTRUCTIONS SHOULD BE INTERPRETED AND APPLIED IN CONJUNCTION WITH 

THE SAFETY RULES AND REGULATIONS APPLICABLE AT THE SITE AND THE PARTICULAR 

REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE.
THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN 

EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN 

CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER 

INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT 

COVERED SUFFICIENTLY FOR THE CUSTOMER/OPERATOR’S PURPOSES THE MATTER 

SHOULD BE REFERRED TO BAKER HUGHES.
THE RIGHTS, OBLIGATIONS AND LIABILITIES OF BAKER HUGHES AND THE CUSTOMER/

OPERATOR ARE STRICTLY LIMITED TO THOSE EXPRESSLY PROVIDED IN THE CONTRACT 

RELATING TO THE SUPPLY OF THE EQUIPMENT. NO ADDITIONAL REPRESENTATIONS OR 

WARRANTIES BY BAKER HUGHES REGARDING THE EQUIPMENT OR ITS USE ARE GIVEN 

OR IMPLIED BY THE ISSUE OF THESE INSTRUCTIONS.
THESE INSTRUCTIONS ARE FURNISHED TO THE CUSTOMER/OPERATOR SOLELY TO 

ASSIST IN THE INSTALLATION, TESTING, OPERATION, AND/OR MAINTENANCE OF THE 

EQUIPMENT DESCRIBED. THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR 

IN PART WITHOUT THE WRITTEN APPROVAL OF BAKER HUGHES.

Содержание Masoneilan 08-80H

Страница 1: ...Masoneilan Model 78 80H 08 80H Transfer Valves Instruction Manual Rev F Baker Hughes Data Classification Public ...

Страница 2: ...R REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION OPERATION OR MAINTENANCE SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE CUSTOMER OPERATOR S PURPOSES...

Страница 3: ...___________________ 5 2 Specifications_______________________________________ 5 3 Certifications________________________________________ 5 4 Numbering System___________________________________ 5 5 Mounting___________________________________________ 5 6 Adjustment_________________________________________ 6 7 Maintenance________________________________________ 6 ...

Страница 4: ...te Indicates important facts and conditions About this Manual The information in this manual is subject to change without prior notice The information contained in this manual in whole or part shall not be transcribed or copied without Baker Hughes s written permission Please report any errors or questions about the information in this manual to your local supplier These instructions are written s...

Страница 5: ...nd 9 2 Specifications Item Standard Option Maximum Operating Pressure Body 1 72 MPa Signal 1 03 MPa Set Pressure 100 700 kPa Hysteresis 34 kPa or less Cv Value IN OUT 4 5 OUT EXH 5 0 Connection IN OUT EXH Ports Rc1 2 NPT1 2 SIGNAL Port Rc1 4 NPT1 4 Operating Temperature Range 30 83 C 0 100 C Housing Material Aluminum Alloy 316L Stainless Steel 1 1 When the housing material is 316L stainless steels...

Страница 6: ...e capacity This may cause hunting 6 Adjustment The necessary settings of the transfer valve are generally performed at the factory and adjustment of it is not required If however the setting pressure needs to be adjusted make adjustment as follows a Loosen the lock screw 26 and turn the adjust knob 17 counterclockwise to release the compression of the spring 25 b Turn the adjust knob 17 one or two...

Страница 7: ...ty 1 Body AC 4B F CHROMATE 1 2 Housing ADC 12 CHROMATE 1 3 Plug SUS303 NBR 1 4 Piston A2017BE T6 CHROMATE NBR 1 7 Spring SUS304 WPB 1 8 O Ring NBR 1 9 O Ring NBR 1 10 O Ring NBR 1 11 O Ring NBR 1 13 Bottom Cap SUS303 1 14 Filter SUS304 2 16 Spring Case ADC12 CHROMATE 1 17 Adjust Knob VALOX420 1 18 Diaphragm Plate SUS303 1 19 Exhaust Orifice SUS303 1 20 Diaphragm NBR DUCRON 1 21 Ball SUS440C 1 22 A...

Страница 8: ...ing Standard Specifications Part N Part Name Material Qty 1 Body AC2A F CHROMATE 1 2 Head Cap AC2A F CHROMATE 1 3 Plug SUS303 NBR 1 4 Piston A2017BE T6 CHROMATE NBR 1 5 Spring SUS304 WPB 1 6 O Ring NBR 1 7 O Ring NBR 1 8 O Ring NBR 1 9 O Ring NBR 1 10 Bottom Cap SUS303 1 11 Screw SUS304 4 12 Nut SUS304 4 ...

Страница 9: ...Masoneilan 78 80H 08 80H Transfer Valves Instruction Manual 9 2021 Baker Hughes Company All rights reserved Notes ...

Страница 10: ...s bakerhughes com Copyright 2021 Baker Hughes Company All rights reserved Baker Hughes provides this information on an as is basis for general information purposes Baker Hughes does not make any representation as to the accuracy or completeness of the information and makes no warranties of any kind specific implied or oral to the fullest extent permissible by law including those of merchantability...

Отзывы: