background image

BAIN DE VILLE

TM

 

INSTALLATION INSTRUCTIONS 

IMPORTANT INFORMATION 

FOR THE INSTALLER AND THE OWNER

 

TO BE KEP

T B

Y THE O

WNER

 

Содержание BAIN DE VILLE

Страница 1: ...BAIN DE VILLE TM INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER T O BE KEPT BY THE OWNER ...

Страница 2: ......

Страница 3: ...UCTIONS 4 5 INTEGRATED WASTE OVERFLOW AND CABLE DRIVEN WASTE OVERFLOW KITS 7 INTEGRATED OVERFLOW CONNECTION PVC PIPE 8 BRASS PIPE 9 CABLE DRIVEN 10 BEDDING AND DRAIN POSITION 11 LEVELING AND TURBINE LOCATION 12 SECURING 13 FRAMING INSTRUCTIONS 14 REMOTE MOUNTING REMOTE TURBINE CONNECTION 15 16 REMOTE TURBINE ELECTRICAL CONNECTIONS 17 THERAPIES ELECTRICAL CONNECTIONS 18 ELECTRICAL DIAGRAMS 19 CUTTI...

Страница 4: ...r alcohol before or during the use of a Hydro thermo massage bathtub equipped with a heater Use this unit only for its intended purposes or as described in this manual Use only accessories or devices recommended by the manu facturer Risk of hyperthermia and possible drowning Check and adjust water temperature before use Water temperature exceeding 100ºF 38ºC may be harmful to your health To reduce...

Страница 5: ...cated circuit copper conductors that resist temperatures of at least 194 F 90 C Canada only for permanently connected units A green colored terminal or a wire connector marked g gr ground or grounding is provided within the terminal compartment not applicable if unit supplied with an electric plug To reduce the risk of electrocution connect this terminal or connector to the grounding terminal of y...

Страница 6: ... Monday to Thursday from 8 a m to 6 p m EST Friday from 8 a m to 5 p m EST Printed in Canada Copyright December 2019 BainUltra Inc All rights reserved 45200689 BAIN DE VILLETM INSTALLATION INSTRUCTIONS BAIN DE VILLETM ...

Страница 7: ...t applications or are protected by patents INSTALLATION INSTRUCTIONS BAIN DE VILLETM TITRE PVC WASTE OVERFLOW KIT THE LENGTH OF THE PIPE MAY VARY DEPENDING ON THE BATHTUB MODEL INTEGRATED WASTE OVERFLOW AND CABLE DRIVEN WASTE OVERFLOW KITS CABLE DRIVEN WASTE OVERFLOW KIT For front overflow tub BRASS WASTE OVERFLOW KIT ...

Страница 8: ...hursday from 8 a m to 6 p m EST Friday from 8 a m to 5 p m EST Printed in Canada Copyright December 2019 BainUltra Inc All rights reserved 45200689 BAIN DE VILLETM INSTALLATION INSTRUCTIONS INTEGRATED OVERFLOW CONNECTION PVC PIPE ...

Страница 9: ...ome products specifications and services mentioned in this manual are described in pending patent applications or are protected by patents INSTALLATION INSTRUCTIONS BAIN DE VILLETM INTEGRATED OVERFLOW CONNECTION BRASS PIPE ...

Страница 10: ...ursday from 8 a m to 6 p m EST Friday from 8 a m to 5 p m EST Printed in Canada Copyright December 2019 BainUltra Inc All rights reserved 45200689 BAIN DE VILLETM INSTALLATION INSTRUCTIONS CABLE DRIVEN WASTE AND OVERFLOW CONNECTION ...

Страница 11: ...ON X DIMENSION Y Bain de Ville 6030 10 3 8 14 1 8 Bain de Ville 6632 10 7 8 15 1 8 DRAIN POSITION BEDDING Before installing ensure that the floor underneath the bath can support 1 500 lbs 680 kg The bath may sit directly on the floor However the bath may also be installed on a bed of concrete For this type of installation it is recommended that you insulate the concrete between two sheets of plast...

Страница 12: ...y to Thursday from 8 a m to 6 p m EST Friday from 8 a m to 5 p m EST Printed in Canada Copyright December 2019 BainUltra Inc All rights reserved 45200689 BAIN DE VILLETM INSTALLATION INSTRUCTIONS LEVELING AND TURBINE LOCATION ...

Страница 13: ...w bainultra com Some products specifications and services mentioned in this manual are described in pending patent applications or are protected by patents INSTALLATION INSTRUCTIONS BAIN DE VILLETM SECURING ...

Страница 14: ...ursday from 8 a m to 6 p m EST Friday from 8 a m to 5 p m EST Printed in Canada Copyright December 2019 BainUltra Inc All rights reserved 45200689 BAIN DE VILLETM INSTALLATION INSTRUCTIONS FRAMING INSTRUCTIONS Ceramic tiles Plywood ...

Страница 15: ...specifications and services mentioned in this manual are described in pending patent applications or are protected by patents INSTALLATION INSTRUCTIONS BAIN DE VILLETM TURBINE REMOTE INSTALLATION SUGGESTED INSTALLATION Parts not included ...

Страница 16: ...eventually fail and void its warranty 6 A 20 Amp GFCI 12AWG 120V dedicated line is needed for the turbine Geysair is powered by the turbine If you have additional options on the bath one or more a second dedicated line is needed 15 Amp GFCI 120V 14AWG GEYSAIR 1 Geysair is installed on the bathtub at the factory and must not be relocated It gets its power from your turbine So per your local electri...

Страница 17: ...ly after all the low voltage wires are connected to turbine If this step has not been done simply disconnect main breaker that is linked to turbine Turbine must be located in a clean and dry space Geysair component cannot be remote mounted Must never be unplugged SEE P 19 FOR ELECTRICAL DIAGRAMS VOIR P 18 POUR SCHÉMAS ÉLECTRIQUES A AromaCloud Aromatherapy B Chromatherapy LED C Mia D MiaPlus Option...

Страница 18: ...MS To GFCI OUTLET United States To GFCI OUTLET United States To Left LED Junction Box Canada Junction Box Canada A WarmTouchShell B Chromatherapy LED C DOT WarmTouchShell D DOT Chromatherapy LED E AromaCloud Aromatherapy Litestreme Inmix module AromaCloud A B E C D DOT WarmTouchShell WTS DOT Chromatherapy LED To Right LED WARNING All electrical connections must be carried out by a certified electr...

Страница 19: ...IT 20A CIRCUIT NEUTRAL N L LOAD NEUTRAL N L LOAD GROUND FAULT CIRCUIT INTERRUPTERS GROUND FAULT CIRCUIT INTERRUPTERS JUNCTION BOX JUNCTION BOX TURBINE WITH GEYSAIR FOR MIAPLUS MIAMULTI TURBINE WITHOUT GEYSAIR FOR MIAPLUS MIAMULTI N L N L 20A THERMOMASSEUR 15A THERAPIES 15A CIRCUIT AIRSTREME WARMTOUCHSHELL N L N L NEUTRAL N L LOAD INMIX MODULE CHROMATHERAPY GROUND FAULT CIRCUIT INTERRUPTERS JUNCTIO...

Страница 20: ...rou pour infrarouge MiaMulti Cut out for MiaMulti infrared 11 313 28 7 cm 1 063 2 7 cm 11 063 28 1 cm 1 625 4 1 cm 1 125 2 9 cm 1 375 3 5 cm 0 875 2 2 cm R0 125 R0 3 cm 1 625 0 04 4 1 cm 0 1 cm AIR INTAKE OPEN PRISE D AIR OUVER Trou pour infrarouge MiaMulti Cut out for MiaMulti infrared 1 063 2 7 cm 1 625 4 1 cm 1 125 2 9 cm 1 375 3 5 cm 0 875 2 2 cm R0 125 R0 3 cm AI PRIS Trou pour infrarouge Mia...

Страница 21: ......

Отзывы: