background image

                   

                       

               

 

3

                                                                                                                               

4

 

 

Battery 

Overheating 

 

Battery level shows current value, battery frame 

blink, fault icon blink 

Load failure 

 

Load overload

  ,Load short circuit 

When load current  reaches1.02-1.05 times 1.05-1.25 times, 1.25-1.35 times and 

1.35-1.5 times more than nominal value, controller will automatically turn off loads in 50s, 

30s,10s and 2s respectively

 

4.3 Load mode setting 

Operating Steps:

                                   

Under load mode setting interface, press SET button and hold on 5s till the number begin 

flashing, then press MENU button to set the parameter, press SET button to confirm. 

Timer 1 

Timer 2 

Light ON/OFF 

Disabled

 

Load will be on for 1 hour 

since sunset 

Load will be on for 1 hour 

before sunrise 

Load will be on for 2 hours 

since sunset 

Load will be on for 2 hours 

before sunrise 

Load will be on for 3

13 

hours since sunset 

Load will be on for 3

13 

hours before sunrise 

Load will be on for 14 hours 

since sunset 

Load will be on for 14 

hours before sunrise 

Load will be on for 15 hours 

since sunset 

Load will be on for 15 

hours before sunrise 

Test mode 

Disabled

 

Manual mode(Default load 

ON) 

Disabled

 

NOTE: Please set Light ON/OFF, Test mode and Manual mode via Timer1. Timer2 

will be disabled and display "2 n". 

4.4 Battery Type 

 

Operating Steps 

Under Battery Voltage interface, press SET  button  and hold on 5s  then  enter into the 

interface of Battery type setting. After choosing the battery type by pressing MENU button, 

waiting for 5s or pressing SET button again to modify successfully. 

 

Battery Type 

Sealed (Default)          

Gel           

Flooded   

NOTE: Please refer to the battery voltage parameters table for the different battery 

type. 

5. Protections                                                  

Protection 

Conditions 

Status 

PV Reverse 

Polarity 

When the battery is correct connecting, the 

PV can be reversed. 

The controller is not 

damage

 

Battery Reverse 

Polarity

 

When the PV is not connecting, the battery 

can be reversed.

 

Battery Over 

Voltage 

The battery voltage reaches to the OVD 

Stop charging 

Battery Over 

Discharge 

The battery voltage reaches to the LVD 

Stop discharging 

Battery 

Overheating

 

Temperature sensor is higher than 65

 

Output is OFF 

Temperature sensor is less than 55

 

Output is ON 

Controller 

Overheating 

Temperature sensor is higher than 85

 

Output is OFF 

Temperature sensor is less than 75

 

Output is ON

 

Load Short 

Circuit 

Load current ≥

2.5 times rated current

  

One short circuit, the output is OFF 5s

 

Two short circuit, the output is OFF 10s

 

Three short circuit, the output is OFF 15s

 

Four short circuit, the output is OFF 20s

 

Five short circuit, the output is OFF 25s

 

Six short circuit, the output is OFF 

Output is OFF 

Clear the fault: 

Restart the controller 

or wait for one 

night-day cycle 

(night time>3 hours).

 

Load Overload 

Load current ≥

2.5 times rated current

  

1.02-1.05 times, 50s, 

1.05-1.25 times, 30s 

1.25-1.35 times,10s 

1.35-1.5 times 2s 

 

Output is OFF 

Clear the fault: 

Restart the controller 

or wait for one 

night-day cycle 

(night time>3 hours).

 

Damaged RTS   

The RTS is short-circuited or damaged 

Charging or 

discharging at 25

 

6. Troubleshooting                                                  

Faults 

Possible reasons 

Troubleshooting 

The LCD is  off 

during daytime when 

sunshine falls on PV 

modules properly 

PV array 

disconnection 

Confirm that PV wire connections 

are correct and tight 

Wire connection is 

correct, LCD not 

display 

1) Battery voltage is 

lower than 9V 

2) PV voltage is less 

than battery voltage 

1)  Please check the voltage of 

battery. At least 9V voltage to 

activate the controller 

2)  Check the PV input voltage 

which should be higher than 

battery’s

 

             

Interface 

blink 

Battery over voltage 

Check if the  battery voltage is 

higher than OVD point (over 

voltage disconnect voltage), and 

disconnect the PV. 

           

Interface 

blink 

Battery   

over discharged 

When the battery voltage is 

restored to  or above LVR point 

(low  voltage  reconnect  voltage), 

the load will recover 

 

Interface                                

blink 

Battery Overheating   

The controller will automatically 

turn the system off. But while the 

temperature  decline to be below 

50 ºC, the controller will resume. 

            

Interface   

blink 

Over load or Short 

circuit 

Please reduce the number of 

electric equipments or check 

carefully loads connection.   

8. Disclaimer                                                

This warranty does not apply under the following conditions: 
1) Damage from improper use or use in an unsuitable environment.

 

2)

 

PV or load current, voltage or power exceeding the rated value of controller. 

3) The controller is working temperature exceed the limit working environment 

temperature. 
4) User disassembly or attempted repair the controller without permission.

 

5) The controller is damaged due to natural elements such as lighting. 
6)

 

The controller is damaged during transportation and shipment. 

7.Technical Specifications                                                                                               

 

Item 

VS1024AU 

VS2024AU 

VS3024AU 

VS3048AU 

VS4524AU 

VS4548AU 

VS6024AU 

VS6048AU 

Nominal system voltage 

12/24VDC 

Auto 

12/24/36/48VDC 

Auto 

12/24VDC 

Auto 

12/24/36/48VDC 

Auto 

12/24VDC 

Auto 

12/24/36/48VDC 

Auto 

Battery input voltage range 

9V

32V 

9V

64V 

9V

32V 

9V

64V 

9V

32V 

9V

64V 

Rated charge/discharge current  10A@55

 

20A@55

 

30A@55

 

45A@55

 

60A@55

 

Max. PV open circuit voltage 

50V 

96V 

50V 

96V 

50V 

96V 

Battery type 

Sealed(Default) / Gel / Flooded 

Equalize Charging Voltage

 

Sealed:14.6V/ Gel: No/ Flooded:14.8V 

Boost Charging Voltage

 

Sealed:14.4V/ Gel:14.2V/ Flooded:14.6V 

Float Charging Voltage

 

Sealed/Gel/Flooded:13.8V 

Low Voltage Reconnect 

Voltage

 

Sealed/Gel/Flooded:12.6V 

Low Voltage Disconnect 

Voltage

 

Sealed/Gel/Flooded:11.1V 

Self-consumption 

9.2

mA/12V;≤

11.7mA/24V; 

14.5mA/36

V;≤

17mA/48V 

Temperature compensation 

coefficient 

-3mV/

/2V

25

℃)

 

Charge circuit voltage drop 

≤0.29V

 

Discharge circuit voltage drop 

≤0.16V

 

LCD temperature range 

-20

℃~

+70

 

Working environment 

temperature   

-25

℃~

+55

(Product can work continuously at full load) 

Relative humidity 

≤95%

, N.C.   

Enclosure 

IP30 

Grounding 

Common Positive 

USB output 

5VDC/2.4A(Total) 

Overall dimension 

142x85x41.5mm

 

160x94.9x49.3mm

 

181x100.9x59.8mm 

194x118.4x63.8mm                     

214x128.7x72.2mm                          

Mounting dimension 

130x60mm

 

148x70mm

 

172x80mm 

185x90mm 

205x100mm 

Mounting hole size 

Φ4.5mm

 

Φ5mm

 

Φ5mm

 

Φ5mm

 

Terminals   

4mm

2

/12AWG

 

10mm

2

/8AWG

 

16mm

2

/6AWG

 

16mm

2

/6AWG

 

25mm

2

/4AWG 

Net weight 

0.22kg 

0.35kg

 

0.55kg 

0.58kg 

0.76kg 

0.88kg 

1.02kg 

1.04kg 

Above the parameters are in 12V system at 25

, twice in 24Vsystem, triple in 36V system and quadruple in 48V system.

 

 

Any changes without prior notice!  

Version number

V1.2

 

3-2

参数设置方式

 

 

 

 

 

 

 

Содержание BTBLANKET120

Страница 1: ...controller Operating Temp 35 to 55 Go off grid with the Baintech 120w Solar Blanket Designed to charge your 4WD RV and Marine batteries this lightweight and compact blanket will produce up to 6 6A in optimal conditions Designed with ease of use in mind the simple plug and play Anderson plug connection is secure safe and easy to connect The Baintech blanket comes with a smart 20amp 12 24v PWM with ...

Страница 2: ... solar blanket offers a simple plug and play solution The blanket comes with a PWM Solar Controller The Solar Controller is normally used when there is no internal controller in your equipment ie when you want to charge your car battery or a secondary battery in a trailer OUTPUT Connect the Anderson connector with solar charger controller and then connect the Alligator clamps to your batteries Alw...

Страница 3: ...t the battery first in order to allow the controller to recognize the system voltage 3 The battery fuse should be installed as close to battery as possible The suggested distance is within 150mm 4 The VS AU series is a positive ground controller Any positive connection of solar load or battery can be earth grounded as required NOTE Please connect the inverter or other load that it has the large st...

Страница 4: ...ns Troubleshooting The LCD is off during daytime when sunshine falls on PV modules properly PV array disconnection Confirm that PV wire connections are correct and tight Wire connection is correct LCD not display 1 Battery voltage is lower than 9V 2 PV voltage is less than battery voltage 1 Please check the voltage of battery At least 9V voltage to activate the controller 2 Check the PV input volt...

Отзывы: