background image

Visit Elsag Bailey on the World Wide Web at http://www.bailey.com

Our worldwide staff of professionals is ready to meet 

your needs for process automation. 

For the location nearest you, please contact the appropriate regional office.

AMERICAS
29801 Euclid Avenue
Wickliffe, Ohio USA 44092
Telephone 1-216-585-8500
Telefax 1-216-585-8756

ASIA/PACIFIC
152 Beach Road
Gateway East #20-04
Singapore 189721
Telephone 65-391-0800
Telefax 65-292-9011

EUROPE, AFRICA, MIDDLE EAST
Via Puccini 2
16154 Genoa, Italy
Telephone 39-10-6582-943
Telefax 39-10-6582-941

GERMANY
Graefstrasse 97
D-60487 Frankfurt Main
Germany
Telephone 49-69-799-0
Telefax 49-69-799-2406

Form I-E96-216A Litho in U.S.A. 1290
Copyright © 1990 by Elsag Bailey Process Automation, As An Unpublished Work
® Registered Trademark of Elsag Bailey Process Automation
™ Trademark of Elsag Bailey Process Automation

Содержание IMCPM01

Страница 1: ...Process Control and Automation Solutions from Elsag Bailey Group E96 216 Configuration Port Module IMCPM01...

Страница 2: ...UIPEMENTS LECTRONIQUES SONT SENSIBLES AUX PERTURBATIONS PAR FR QUENCE RADIO DES PR CAUTIONS DEVRONT TRE PRISES LORS DE L UTILISATION DU MAT RIEL DE COMMUNICATION PORTATIF LA PRUDENCE EXIGE QUE LES PR...

Страница 3: ...operation and maintenance of the CPM module It addresses handling precautions and installation procedures System engineers and technicians should read this manual before installing and operating the...

Страница 4: ...3 3 Original 4 1 through 4 2 Original 5 1 Original 6 1 Original When an update is received insert the latest changed pages and dispose of the super seded pages NOTE On an update page the changed text...

Страница 5: ...ecautions to insure that contact with energized parts is avoided when servicing AVERTISSEMENT D ORDRE GENERAL Environment de l Equipement Ne pas soumettre les composants a une atmosphere corrosive lor...

Страница 6: ...SECTION 3 INSTALLATION 3 1 INTRODUCTION 3 1 UNPACKING AND HANDLING 3 1 Special Handling 3 1 General Handling 3 1 SETUP AND INSTALLATION 3 1 Physical Installation 3 1 WIRING CONNECTIONS AND CABLING 3...

Страница 7: ...ections 4 2 5 1 Maintenance Schedule 5 1 List of Figures No Title Page 1 1 IMCPM01 Application Example 1 1 2 1 Configuration Port Module 2 1 2 2 IMCPM01 Input Output Circuit 2 2 3 1 IMCPM01 Cable Conn...

Страница 8: ...1 1 shows the INFI 90 Network 90 communication levels and where the CPM module is within these levels Refer to the Con figuration and Tuning Terminal Product Instruction Manual for more details about...

Страница 9: ...r through the MMU Digital signals between the CTT and the master modules also pass through the P1 connector FEATURES The modular design of the CPM module as with all INFI 90 modules allows for flexibi...

Страница 10: ...a card cage that provides electrical and communication sup port for INFI 90 modules Module Bus A peer to peer communication path for point data transfer between intelligent mod ules within a process c...

Страница 11: ...0 Littlefuse 312 500 Buss AGC 1 2 Power Consumption Power consumed is that of the CTT0_ CTT02 uses 85 mA at 5 VDC Environmental Specifications Ambient Temperature Relative Humidity Atmospheric Pressur...

Страница 12: ...S Digital signals to and from the CTT are 5 VDC Section 3 explains the module connections Input and Output Circuit Description Figure 2 2 shows the board circuitry on the CPM module The board circuitr...

Страница 13: ...edge connector P1 shown in Figure 2 1 MODULE BUS The module bus provides a 83 3 kilobaud peer to peer commu nication link capable of supporting up to 32 drops Figure 2 2 IMCPM01 Input Output Circuit 2...

Страница 14: ...verify that it has not been damaged in transit 2 Notify the nearest Bailey Controls Sales Office of any ship ping or handling damage 3 File a claim for any damage with the company that handled the shi...

Страница 15: ...system WIRING CONNECTIONS AND CABLING The CPM has one card edge connector P1 to supply logic power and provide digital communications It has a five pin connector on the faceplate to connect the CTT Wi...

Страница 16: ...The CPM has a 0 5 Amp on board fuse Use only a 0 5 Amp 250 Volt fuse Bailey P N 194776A15000 Littlefuse P N 312 500 Bussman AGC 1 2 or equivalent PRE OPERATING ADJUSTMENTS You do not have to make any...

Страница 17: ...screws on face plate one half turn The module is unlocked when the notch on each screw is vertical and the open end is pointing away from the center of the module 3 Gently slide the module out of the...

Страница 18: ...signals and power P1 Table 4 1 shows the P1 pin connections Figure 4 1 IMCPM01 Fuse Location TP35834A P1 IMCPM01 CONNECTS TO CTT J1 F1 1 2 3 4 5 Table 4 1 P1 Pin Connections Pin Connection Pin Connec...

Страница 19: ...HEDULE Do the tasks in Table 5 1 at the noted times Table 5 1 Maintenance Schedule Task Interval Clean and tighten all power and grounding connections Check fuses and holders Every 6 months or during...

Страница 20: ...numbers if used 3 Bailey Controls manual number page number and figure that shows the part When you order standard parts from Bailey Controls use part numbers and descriptions from the Spare Parts Li...

Страница 21: ...756 ASIA PACIFIC 152 Beach Road Gateway East 20 04 Singapore 189721 Telephone 65 391 0800 Telefax 65 292 9011 EUROPE AFRICA MIDDLE EAST Via Puccini 2 16154 Genoa Italy Telephone 39 10 6582 943 Telefax...

Отзывы: