24
24
PRESS FUNCTIONS
Main Disconnect Switch
The main disconnect switch is located on the
front of the electrical cabinet.
•
Turn the switch to the ON position to supply
power to the electrical controls. The red
indicator will light up as long as the
disconnect is ON.
•
Turn the switch to the OFF position to
remove power to the operation controls.
On and Off Switches
The on and off switches are positioned on the
front of the electrical cabinet.
•
Press and release the green button will start
the motor of the hydraulic unit. There will be
no movement of any parts after the motor
runs. The green indicator will light up as long
as the motor is running.
•
Pushing the red button will stop the motor of
the hydraulic unit. All parts will stay in the
position they are at that moment.
Emergency Switch
The emergency switch is located on the front of
the electrical cabinet and at the side press
operators’ station.
In the event of incorrect operation or dangerous
conditions, the machine can be stopped immediately by pressing the
E-STOP
button. All other
parts will stay in the position they are at the moment. Twist the emergency stop button clockwise
(cw) to reset. Note: Resetting the E-Stop will not start the machine.
To restart the hydraulic unit again
•
Make sure the incorrect or dangerous situation is solved.
•
Reset the red button by turning it counterclockwise. The button cap will pop-up again.
•
Actuate the hydraulic lever to the up and down position to relieve pressure from the hydraulic
system.
•
Push the green start button to start the hydraulic pump motor.
Содержание HSP-60M-C
Страница 37: ...34 34 OVERALL MACHINE PARTS DIAGRAM...
Страница 40: ...37 37 MAIN RAM PARTS DIAGRAM...
Страница 42: ...39 39 SIDE RAM PARTS DIAGRAM...
Страница 45: ...42 42 ELECTRICAL SCHEMATIC...
Страница 46: ...43 43 HYDRAULIC DIAGRAM...