35
35
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE (S)
CORRECTIVE ACTION
Pump is Working But The
Ram Will Not Move.
The oil pipe is loose.
The ram is leaking
Tighten pipe connections.
Replace the oil seals.
When Release Valve is
Opened, Ram Does Not
Reset.
The oil pipe is loose
Not enough space in the pump.
Ram is damaged
Tighten pipe connections.
Open the exhaust valve.
Replace the ram.
Sound From Air Motor
But Ram Does Not Work.
Release valve not completely
closed.
Air in system.
Check and close the release
valve.
Purge the system
Ram Can Not Complete
Stroke.
Not enough hydraulic oil.
Add sufficient oil
Air Motor Does Not
Work.
Not enough air pressure or
exceeded the capacity.
Air motor is damaged.
Check the air pressure and
capacity.
Replace the air motor. Contact
Baileigh Industrial at
920.684.4990
Leaking oil
Damaged or worn out cylinder
seals.
Screwed parts loose.
Damaged hose or hoses.
Replace the seals.
Re-tighten screws.
Contact Baileigh Industrial at
920.684.4990