BaiCells CW0100 CPE Installation Guide 

V1.0 

 

 

 

Содержание CW0100

Страница 1: ...All rights reserved BaiCells Technologies Co Ltd BaiCells CW0100 CPE Installation Guide V1 0...

Страница 2: ...d in any form or means without the prior written consent of BaiCells Disclaimer This specification is preliminary and is subject to change at any time without notice BaiCells assumes no responsibility...

Страница 3: ...2 LED Indicators 6 2 3 RF Specifications 6 2 4 Install on Pole 7 2 5 Install on Wall 8 2 6 3 Wire Connection 9 Make Ethernet Cable Connector 9 3 1 Connect Ethernet Cable 13 3 2 Power On 14 3 3 Lightn...

Страница 4: ...yer 9 Figure 3 3 Cut off the aluminum foil layer of twisted pair 10 Figure 3 4 Color Order 10 Figure 3 5 Insert the twisted pair core into line card 10 Figure 3 6 Insert line card into Connector 11 Fi...

Страница 5: ...Contents of Table Table 2 1 CW0100 Interface and button 5 Table 2 2 LED Indicators 6 Table 2 3 RF Specification 6 Table 3 1 Lightning Protection Demand of Cable 15...

Страница 6: ...Check whether the material in the box is consistent with Shipping List and is in good condition and undamaged Note During the unpacking if the outer package is damaged or soaked stop unpacking and fin...

Страница 7: ...installation site Plastic tie Grounding wire Installation Tools 1 3 The following tools are needed during the installation Standing wave measuring instrument Nipper pliers Diagonal pliers Pincer plier...

Страница 8: ...g to Reconnaissance Report check whether the external environment of installation site is ready Safety Protection 1 5 Construction personnel must conform to Construction Safety Specification wearing s...

Страница 9: ...igure 2 1 Appearance of CW0100 CW0100 CPE support installing on pole or installing on wall The following introduces the two ways separately Caution The direction of CPE cable exit end must be down Int...

Страница 10: ...n Connected the signal is weak Two LED Steady On Connected the signal is medium Three LED Steady On Connected the signal is strong LAN Eth Indication Green OFF Ethernet connection is not established S...

Страница 11: ...0mm and diameter is 25mm to 45mm as the mounting bracket Iron on tower If CPE is installed on iron tower you need to choose vertical direction angle iron as the mounting bracket The length is about 25...

Страница 12: ...talls on wall the installation method is as follows On the wall fix two big head screw which distance is 52mm and then hang the CPE on the big head screw Figure 2 4 Mounting Hole of Install on Wall Fa...

Страница 13: ...strip the outer Jacket of the twisted pair about 30mm using crimping tool which is shown in Figure 3 1 Figure 3 1 Strip Shielded Twisted Pair 2 Separate the metal net wire of cable and aluminum foil l...

Страница 14: ...4 Color Order 5 Insert the eight wires into the line card according to the color order shorten them to a suitable length about 12 mm using diagonal pliers as shown in Figure 3 5 Figure 3 5 Insert the...

Страница 15: ...crimper as shown in Figure 3 7 Figure 3 7 Crimping connector 8 Impact the metal part of the shielded connector tail with the metal net shielded layer of the Ethernet cable using nipper pliers as show...

Страница 16: ...fter the completion of shielded connector making as shown in Figure 3 10 Repeat all the steps and wire color on the other end of the cable Figure 3 10 Completion of shielded connector 11 Test whether...

Страница 17: ...ny signal indicator is red or yellow it indicates that there is circuit break or bad contact You need to make a new connector again Connect Ethernet Cable 3 2 1 Connect the shielded cable to WAN inter...

Страница 18: ...0 outdoor CPE is powered with POE CPE provides standard POE power interface conformed to IEEE 802 3af standard The 4 5 7 8 wire have direct current Before power on test whether there is voltage output...

Страница 19: ...leeve It is highly recommended that the distance is as nearest as possible between the two equipment connected by Ethernet cable avoiding the cable hanging in the air According to the wiring environme...

Страница 20: ...ng CPE IP address normal CPE Configuration Check 4 3 Log in the WebUI of CPE check whether the software version is correct whether the LTE mode is enabled and whether WAN interface and LAN interface a...

Страница 21: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur...

Страница 22: ...s de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique s...

Страница 23: ...TE network CPE receive download signal weak If external antenna is used check whether antenna feed system have connected normal The standing wave measuring can be used Check whether the internal coaxi...