Aurora243 Outdoor 2x10W TDD gNodeB Installation Guide
10
2.
Installation Preparation
2.1 Materials
Check the Aurora243 package to ensure it contains the primary components shown in the pack out
(Figure 2-1). In addition to industry-standard tools, you will need the materials described in Table 2-1
and the tools described in Table 2-2 during the installation.
Figure 2-1: Aurora243 Pack Out
Table 2-1: Materials
Item
Description
DC power cord
A DC cable is provided with the device. If the length is insufficient, prepare 13 AWG cable,
with two cores, less than 330 ft (100m).
AC power cord
(optional)
If the power supply
is AC, prepare
13 AWG or greater (e.g., 12 AWG) cable, with three
cores, less than 328 feet (100 meters).
Power supply
90 VAC to 264 VAC, 47 Hz to 63 Hz
RF antenna cable
50-ohm feeder, ½ jumper
RF antenna
Omni or directional dual-polarized. Ensure the frequency range of the RF antenna
matches the gNB.
Optical fiber
Optical fiber (armor). It is suggested that the diameter of the cable is 0.3 inches ± 0.04
inches (7 mm ± 1 mm)
Ethernet cable
Outdoor CAT6, shorter than 328 feet (100 meters). It is suggested that the diameter of
the cable is 0.3 inches ± 0.04 inches (7 mm ± 1 mm)
Ground cable
If the length of the lead is more than 33 feet (10 meters), use 8 AWG (10 mm²).
If the length of the lead is less than 33 feet (10 meters), use 8 AWG (10 mm²).