background image

 

11 

 

Using  grounding  cable,  connect  the  grounding  screw  to  the  ground  row,  as  shown  in 

Figure 3-6.

 

Figure 3-6 Grounding 

 

 

3.6

 

Regulatory Compliance 

FCC Compliance 

This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to  the 

following two conditions: (1) This device may not cause harmful interference, and (2) 

this  device  must  accept  any  interference  received,  including  interference  that  may 

cause undesired operation. 

Any  Changes  or  modifications  not  expressly  approved  by  the  party  responsible  for 

compliance could void the user's authority to operate the equipment. 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  A 

digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to 

provide  reasonable  protection  against  harmful  interference  when  the  equipment  is 

operated  in  a  commercial  environment.  This  equipment  generates,  uses,  and  can 

radiate radio frequency energy and, if not installed and used in accordance with the 

instruction  manual,  may  cause  harmful  interference  to  radio  communications. 

Operation  of  this  equipment  in  a  residential  area  is  likely  to  cause  harmful 

interference in which case the user will be required to correct the interference at his 

own expense. 

Warning 

This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an 

Содержание EG7035E-M1

Страница 1: ...01 All rights reserved Baicells Technologies Co Ltd Baicells EG7035E M1 User Manual V100R001C00...

Страница 2: ...Baicells Disclaimer This specification is preliminary and is subject to change at any time without notice Baicells assumes no responsibility for any errors contained herein For more information pleas...

Страница 3: ...pecification 6 3 Installation Guide 8 3 1 Support Materials 8 3 2 Install USIM Card and Ethernet Cable 8 3 3 Install on Pole 9 3 4 Install on Wall 10 3 5 Grounding 10 3 6 Regulatory Compliance 11 4 Co...

Страница 4: ...Appendix B Shipping List 19...

Страница 5: ...0 Figure 3 6 Grounding 11 Figure 4 1 Login Page 13 Figure 4 2 View Status 14 Figure 4 3 Set Connection Method 14 Figure 4 4 Set Scan Mode 15 Figure 4 5 Lock Frequency 16 Figure 4 6 Lock Frequency 17 T...

Страница 6: ...ensive routing capabilities which have the abilities to bring the end users WBB services 1 2 Features The EG7035E M1 is designed according to the simplicity principle which can evolve in a short perio...

Страница 7: ...35E M1 The EG7035E M1 interface and button description is given in Table 1 1 Table 1 1 Description of EG7035E M1 Interface and Button Interface Button Description PoE Connected to the PoE power adapte...

Страница 8: ...Description Color Status Description MIU Yellow OFF Reserved Steady On Reserved Blanking Reserved LTE Network state Indicator Blue OFF LTE disconnected Steady On LTE connected SIM SIM card status ind...

Страница 9: ...5 LTEs Indicate connection state and signal strength Green All OFF Signal is too weak to attach Steady On According to signal strength in turn light up Blanking Scanning the LTE network The CPE is aut...

Страница 10: ...restore the factory settings Power Supply Input Universal range 100V 240V AC Dimension About 248mm 248mm 80mm Weight About 1800g Color Pantone white C 2 2 RF Specification Table 2 2 RF Specification...

Страница 11: ...ger DMZ UPnP Statistics LAN Link Status Transmit Receive traffic Running Time 2 4 Device Management Table 2 4 Device Management Item Description Maintenance Date Time setting Reset Restore factory set...

Страница 12: ...7 Table 2 5 Environment Specification Item Description Operating Temperature 40 55 Storage Temperature 40 70 Operating Humidity 5 95...

Страница 13: ...tall USIM Card and Ethernet Cable 1 Screw the two screws on the waterproof cover 2 Open the waterproof cover and connect the Ethernet cable to the Ethernet interface 3 Insert the USIM card to the USIM...

Страница 14: ...agram 6 Power on the LED indicator will light up 3 3 Install on Pole 1 Tighten the screws at the bottom of the bracket as shown in Figure 3 3 Figure 3 3 Install the Bracket 2 Install the bracket on po...

Страница 15: ...3 4 Install on Pole 3 4 Install on Wall Install bracket on wall as show as Figure 3 5 Figure 3 5 Install on Wall 3 5 Grounding The EG7035E M1 must be grounding please contact professional person to o...

Страница 16: ...ate the equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable p...

Страница 17: ...not be collocated or operating in conjunction with any other antenna or transmitter End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance Les antennes...

Страница 18: ...nter the user name and password click LOGIN After password authentication you can log on to the web management page The default user name and password is admin For security it is recommended that you...

Страница 19: ...ollowing steps 1 Choose LTE 2 In the LTE Setting area configure the LTE network 4 3 2 Set Connection Method To set the LTE network connection method perform the following steps 1 Choose LTE connection...

Страница 20: ...mode perform the following steps 1 Choose LTE Scan Method enter the setting scan method page as shown in Figure 4 4 Figure 4 4 Set Scan Mode 2 In the Scan Method area set the scan mode 3 You can choos...

Страница 21: ...o lock the PCI perform the following steps 1 Choose LTE Scan Method 2 In the LTE Scan Method area click PCI Lock to lock the PCI 3 Click ADD LIST you can choose a band frequency and PCI then click Add...

Страница 22: ...17 Figure 4 6 Lock Frequency 4 Click SAVE APPLY...

Страница 23: ...uctions such as concrete or wooden walls Check that the CPE is placed far away from household electrical appliances that generate strong electromagnetic field such as microwave ovens refrigerators and...

Страница 24: ...List The product outward appearance the color take the material object as the picture only supply reference Index Content Picture Amount 1 EG7035E M1 CPE 1 2 Power cord 1 3 PoE adapter 1 4 Mounting br...