9
EN
Before each use:
- General cleaning.
- Inspect the device for correct operation of the hydraulic system.
- Visual inspection for damage and/or leaks.
- Check the hydraulic and/or pneumatic hoses for damage or leaks.
- Check that welds are not damaged.
- Check that all bolts and connections are in place and tight.
- Check that wheels are free of soiling.
Every three months or as necessary (depending on usage):
- Check the hydraulic oil level.
- Lubricate moving parts.
Every 1 year or as necessary (depending on usage)
- Change the hydraulic oil.
Troubleshooting
The identification of problems and potential remedies presuppose compliance with all preventive and safety
measures detailed in the following sections of the user manual:
Warnings and Safety Instructions
Intended Use and Operation
Maintenance and Repair
Warranty
PROBLEM
POTENTIAL CAUSE
REMEDY
Load not lifted
Pressure relief valve open
Close the pressure relief valve according to the
instructions provided.
Externally clean the relief system.
Low oil level or no oil
Top up to the correct level and purge the circuit
according to the instructions provided.
Air in hydraulic system
Purge the circuit according to the instructions
provided.
Load exceeds rated capacity
Ensure that the load does not exceed the capacity of
the device.
Pressure relief valve and/or
overpressure valve not working
properly
Externally clean the relief system.
Change the hydraulic oil.
Contact an authorized distributor or SNA Europe SAS.
Load partially lifted
Insufficient oil
Check the oil level; top up to the correct level and
purge the circuit according to the instructions
provided.
Load lifted slowly
Air in hydraulic system
Purge the circuit according to the instructions
provided.
Hydraulic leak
Contact an authorized distributor or SNA Europe SAS.
Load lifted but not
held
Air in hydraulic system
Purge the circuit according to the instructions
provided.
Hydraulic leak
Contact an authorized distributor or SNA Europe SAS.
Load not lowered or
lowered slowly
Pressure relief valve closed or
partially closed
Open the pressure relief valve according to the
instructions provided.
Externally clean the relief system.
Internal parts damaged
Contact an authorized distributor or SNA Europe SAS.
Friction between moving parts
Properly lubricate moving parts.
Содержание BH15000B
Страница 3: ...2 3 m 4 5 6 3 1 2...
Страница 4: ...4 BH15000B BH110000B...
Страница 5: ...5 4 BH15000B 540 ml BH110000B 1050 ml...
Страница 6: ...6 BH15000B BH110000B...
Страница 56: ...56 BH15000B BH110000B 400 EN 1494 2000 A1 2008 ISO VG15...
Страница 57: ...57 RU SNA Europe SAS SNA Europe SAS SNA Europe SAS SNA Europe SAS...
Страница 58: ...58 BH15000B BH110000B https www bahco com ru_ru warranty...
Страница 72: ...72 BH15000B BH110000B 400 EN 1494 2000 A1 2008 ISO VG15...
Страница 73: ...73 EL 1 SNA Europe SAS SNA Europe SAS SNA Europe SAS SNA Europe SAS...
Страница 74: ...74 BH15000B BH110000B https www bahco com int_en warranty...
Страница 79: ......