6
Trouble shooting diagram for light oil burner
TROUBLE OBSERVED
INSTRUMENT READING
POSSIBLE CAUSES
CORRECTION
General trouble
incorrect basic adjustment
check basic settings
check power supply
Motor of burner does not turn
stage 1
no power supply
check power supply
operate overload switch at generator
Burner on, but no flame
malfunction lamp burns
vacuum gauge exceeds 0,4 bar
filter blocked
replace filter cartridge
clean filter strainer
vacuum gauge remains below
0,4 bar
pressure gauge does not rise
pump entrains air
fill fuel oil tank
replace O-rings
check suction line for leaks
shut vent cock
vacuum gauge remains below
0,4 bar
photosensor gets outside light
push photosensor into bushing,
glass side should be towards tumbler
pressure gauge at:
nozzle blocked
replace nozzle
13 bar - BA 7 / 16 bar - BA 10
no ignition spark
check transformer, cables and ignition
electrodes;
replace ignition electrodes
solenoid valve defective
check plug for proper seating; check and,
if necessary, replace solenoid valve
incorrect voltage
check generator voltage 230V 50Hz;
tense V-belt
adjust engine speed
oil firing control defective
replace oil firing control
Burner on, flame on, but goes
out again
vacuum gauge below 0,4 bar
pressure gauge at:
photosensor defective
check connection of photosensor
if necessary replace photosensor
malfunction lamp burns
13 bar - BA 7 / 16 bar - BA 10
incorrect burner head
adjustment
check basic settings
oil firing control defective
replace oil firing control