manualshive.com logo in svg
background image

13

 

    DISPLAY MANUAL 

DP C18.UART

USER SET

 “TRIP Reset” --- set reset function for 

single-trip distance

Briefly press (<0.5S) 

 or   to select “TRIP 

Reset”,and then briefly press (<0.5S) 

 . 

This moment, briefly press (<0.5S) 

 or   

to switch between “NO” and “YES”. TRIP Re-
set includes maximum speed (MAXS), aver-
age speed (AVG), single-trip distance (TRIP). 
After confirmation, briefly press (<0.5S) 

 

again to save the set and exit back to the 
“TRIP Reset”. Briefly press 

 for two times 

(interval time is less than 0.5S) to exit the 
main interface, or select “BACK” 

 “EXIT” 

to exit back to the main interface. The data 
is not reset automatically when turn off the 
display or turn off the power of the bicycle.

 “Wheel” --- set the wheel diameter

Briefly press (<0.5S) 

 or   to select 

“Wheel”, and then briefly press (<0.5S) 

 . 

This moment, briefly press (<0.5S) 

 or   

to select the wheel diameter as “6”/“7”/“8”/ 
……/“32”/“33”/“34”. After confirmation, 
briefly press (<0.5S) 

 to save the set and 

exit back to “Wheel”. Briefly press 

 for 

two times (interval time is less than 0.5S) to 
exit back to main interface or select “BACK” 

 “EXIT” to exit back to main menu.

 “Speed Limit” --- set speed limit

Briefly press (<0.5S) 

 or   to select 

“Speed Limit” and then briefly press (<0.5S) 

 . This time, briefly press (<0.5S) 

 or 

 to select the number as “10”/“11”/“12

”/……/“58”/“59”/“60”. After confirmation 
, briefly press (<0.5S) 

 to save the set 

value and exit back to “Speed Limit”. Briefly 
press 

 for two times (interval time is less 

than 0.5S) to exit back to main interface or 
select “BACK” 

 “EXIT” to exit back to main 

interface.

 “AL Sensitivity” --- set light  sensitivity

Briefly press (<0.5S) 

 or   to select “AL 

Sensitivity”, and then briefly press (<0.5S) 

 . This moment, briefly press (<0.5S) 

 

or   to switch level of the light sensitivity 
between “0”/“1”/“2”/“3”/“4”/“5”/“OFF”. 
“OFF” means close the function. Level 1 is 
the weakest light sensitivity and level 5 is 
the strongest light sensitivity. Select the level 
desired and briefly press (<0.5S) 

 again to 

save the setting and exit back to “AL Sensi-
tivity”. Briefly press 

 for two times (interval 

time is less than 0.5S) to exit back to main 
interface or select “BACK” 

 “EXIT” to exit 

back to main interface.

⑾ 

“Factory Setting”--- Restore factory Set-

tings

Briefly press (

<

0.5S) 

 or   to select “Fac-

tory Setting” and then  briefly press (<0.5S) 

 . This moment, briefly press (<0.5S) 

 

or   to select “YES” / “NO”. Select “YES” 
and briefly press (<0.5S) 

 . When display 

the “OK”, it means it is successful to restore 
the factory setting. Briefly press 

 for two 

times(interval time is less than 0.5S) to exit 
back to main interface or select “BACK” 

 

“EXIT” to exit the main interface.

 “Password”--- boot password setting

Briefly press (

<

0.5S) 

 or   to select “Pass-

word” and then briefly press (<0.5S) 

.   

This momen, briefly press (<0.5S) 

 or   

to select “Start PassWord” and then briefly 
press (<0.5S) 

 again. Briefly press (<0.5S) 

 or to switch between “OFF” / “ON”, the 

below is the specific way of switching.

Starting password:

Enter into “Start PassWord” interface and  
select “ON”. Briefly press (<0.5S) 

 , and 

then it show input password in the interface. 

Содержание DP C18.UART

Страница 1: ...C18 UART CONTENT Content 1 Introduction 2 Overview drawing 3 Specifications 4 Functional overview 5 Normal indication area 6 Button definition 7 Normal operation 7 User set 10 Error code definition 17...

Страница 2: ...play model 1 0 hardware version number B Down row number as below 605P1QB220003 605 Wire length and connector model is 230mm M5 2 P1 design number QB220003 Production date is 21st Nov 2016 SN is 0003...

Страница 3: ...3 DISPLAY MANUAL DP C18 UART OVERVIEW DRAWING OVERVIEW DRAWING...

Страница 4: ...8V DC Rated current 10mA lines as shown in the figure Maximum operating current 30mA When power off leak current is less than 1uA Operating current supplied to controller 50mA Operation temperature 20...

Страница 5: ...utomatically turned on off depending on lighting conditions 5 levels off display backlighting 10 is most dark 100 is highest light 6 Level Support setting power Levels 0 to 5 Trip distance indication...

Страница 6: ...level display Display current battery level value 7 Voltage display percentage display Display actual battery level value display mode can be set in the Soc View 8 Speed digital display Display curren...

Страница 7: ...utes time can be set in Auto Off the display will be automatically turned off If the password function of the display is activated need to input the correct password to enter into the normal display i...

Страница 8: ...Briefly press 0 5s to switch the display between the distance and speed cycle show signal trip distance TRIP total distance ODO maximum speed MAX average speed AVG remaining distance RANGE energy con...

Страница 9: ...er can be set in the Brightness If the display is turned on in a dark environment the display backlight headlight will be turned on automatically If the display backlight headlight are turned off manu...

Страница 10: ...ocess in the set interface AL Sensitivity Default Mode Unit Brightness Auto Off Power View SOC View TRIP Reset Factory Setting Password Set clock BACK Default Mode Wheel Speed Limit BACK Battery info...

Страница 11: ...and enter into Display setting There are thirteen set options in the interface Unit unit switch between the km and mile Briefly press 0 5S or to select Unit and then briefly press 0 5S to enter into...

Страница 12: ...press for two times interval time is less than0 5S to exit back to main interface or select BACK EXIT to exit the main menu Power View set output display mode Briefly press 0 5S or to select Power Vie...

Страница 13: ...nterval time is less than 0 5S to exit back to main interface or select BACK EXIT to exit back to main interface AL Sensitivity set light sensitivity Briefly press 0 5S or to select AL Sensitivity and...

Страница 14: ...ess than 0 5S to exit back to main interface or select BACK EXIT to exit back to main interface Change password After setting the password the interface Password will add option Reset Password Briefly...

Страница 15: ...ect Set Clock and then briefly press 0 5S The time is represented in the 24 hour system Cursor stays at the first digit of the clock Briefly press or to select 0 2 and then briefly press 0 5S to confi...

Страница 16: ...Max Uncharge Time Current current Last Uncharge Time Last Uncharge Time Res Cap remaining battery capacity Total Cell The number of cell Full Cap Battery capacity of Full charged Cell Voltage 1 Volta...

Страница 17: ...nsor inside Have your dealer check the motor stator 10 The motor temperature reaches to the max protection value Stop riding and wait until the LED stop flickering 12 Fault with current sensor inside...

Страница 18: ...18 DISPLAY MANUAL DP C18 UART NOTES...

Страница 19: ...19 DISPLAY MANUAL DP C18 UART NOTES...

Страница 20: ...20 DISPLAY MANUAL DP C18 UART NOTES...

Отзывы: